Pepperl+Fuchs 200660

NDP-KE2-8E2

WIS module primary

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Fa

Technical parameters

Operating voltage: 24 V DC ± 10 %
Number of signal channels: 8
Signal transfer direction: from secondary side to primary side
Reverse polarity protection: reverse polarity protected
Current consumption: max. 1000 mA
MTTFd: 245 a
Mission Time (TM): 20 a
Diagnostic Coverage (DC): 0 %
Switching state: 8 x LED, yellow
Transfer indicator: LED, green
Number: 1
Input type: Activation input signal level: ≥ 15 V = active, ≤ 3 V inactive
Input current: ≤ 1 mA
Internal resistor: ≥ 15 kΩ
Output type: 1 Status output (high with proper transfer) and 8 Switch outputs PNP, NO. (switched high) , overload and short-circuit resistant
Voltage drop: ≤ 2.5 V
Load current: max. 50 mA
Response time: ≤ 200 ms ( static operation , the transmission heads stand opposite to each other )
Directive conformity: EMC Directive 89/336/EEC: EN 61000-6-2:2001, EN 61000-6-4:2001, EN 50295:1999
CCC approval: CCC approval / marking not required for products rated ≤36 V
Ambient temperature: 0 ... 50 °C (32 ... 122 °F)
Storage temperature: -25 ... 85 °C (-13 ... 185 °F)
Degree of protection: IP20
Material: Housing: PA 66-FR
Installation: DIN rail mounting
Mass: 106 g
Note: Maximum cable length between WIS module and WIS transmitter must not exceed 5 m.

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m