199290-0014
WCS3B-LS221H
Read head
Read head, RS-485 interface,, with RS-485 termination resistor, RS-485 interface, Non-contact, absolute position encoder, Automatic detection of dirt accumulation, Extended temperature rangefa
| Passage speed: | ≤ 12.5 m/s |
| Measuring range: | max. 314.5 m |
| Free tolerances to code rail: | horizontal: 31 mm ( ± 15.5 mm ) vertical: 28 mm ( ± 14 mm ) |
| Resolution: | ± 0.4 mm (1,250 positions/m) |
| MTTFd: | 60 a |
| Mission Time (TM): | 10 a |
| Diagnostic Coverage (DC): | 0 % |
| Operation indicator: | LED green: power on |
| Data flow indicator: | LED yellow: data communication active |
| Error indicator: | LED red flashing: read head outside of code rail solid on: internal diagnostic test failed |
| Operating voltage: | 10 ... 30 V DC |
| Power consumption: | 11 VA at 24 V DC |
| Interface type: | RS 485 interface |
| Data output code: | binary code |
| Protocol: | 1 , 2 |
| Transfer rate: | 62.5 kBit/s |
| Address: | 0 |
| Termination: | with RS 485 termination |
| Emitted interference: | DIN EN 61000-6-4 , DIN EN 12015 |
| Noise immunity: | DIN EN 61000-6-2 , DIN EN 12016 |
| Shock resistance: | DIN EN 60068-2-27, half sine 30 g, 18 ms |
| Vibration resistance: | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles |
| CSA approval: | cCSAus Certified, General Purpose Class 2 power source |
| CCC approval: | CCC approval / marking not required for products rated ≤36 V |
| Operating temperature: | -40 ... 60 °C (-40 ... 140 °F) |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity: | 90 % , noncondensing |
| Connection type: | 5-pin, M12 x 1 connector |
| Degree of protection: | IP54 |
| Material: Housing: | ABS , PC (Polycarbonate) |
| Mass: | 500 g |
| Ordering information: | Mounting plate included with delivery |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.00 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |