Pepperl+Fuchs 199092

PMI360D-F130-IE8-V15

Ind. angular measuring system

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Measuring range 0 .. 360°, Analog output 4 mA ... 20 mA, Adjustable switch pointsfa

Technical parameters

Installation: non-flush
Measurement range: 360°
Rotational speed: max. 100 min-1
Operating voltage: 18 ... 30 V
Reverse polarity protection: reverse polarity protected
Repeat accuracy: ± 0.25 °
Resolution: 0.4°
Temperature drift: 0.02 ° / °C (-25 °C ... 70 °C)
No-load supply current: ≤ 45 mA
Operating voltage indicator: LED green
MTTFd: 265 a
Mission Time (TM): 20 a
Diagnostic Coverage (DC): 0 %
Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected
Operating current: ≤ 100 mA
Voltage drop: ≤ 3 V
Short-circuit protection: pulsing
Output type: 1 current output: 4 ... 20 mA
Linearity error: ± 0.6 ° , (with original actuator)
Load resistor: ≤ 400 Ω
Standard conformity: Standards: EN 60947-5-2:2007 IEC 60947-5-2:2007
UL approval: cULus Listed, General Purpose, Class 2 Power Source
CCC approval: CCC approval / marking not required for products rated ≤36 V
Ambient temperature: -25 ... 70 °C (-13 ... 158 °F)
Storage temperature: -40 ... 100 °C (-40 ... 212 °F)
Connection type: 5-pin, M12 x 1 connector
Housing material: PBT
Shaft diameter: max. 27.5 mm Steel
Degree of protection: IP67
Mass: 180 g

Logistic parameters

ECCN:
Country of Origin: SG
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m