Pepperl+Fuchs 192436

VAA-2E-F85A-S-V1

AS-Interface EMERGENCY STOP button

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

This AS-Interface emergency shutoff button is a two-channel, positively driven contact, allowing the operation of personnel protection systems when used according to specification along with an AS-Interface safety monitor. It occupies one complete address in the AS-Interface strand. AS-Interface EMERGENCY STOP buttonfa. When the safety monitor is properly configured, up to EN 954-1 Category 4 and IEC 61508 SIL 3 can be achieved. For mounting, the housing of this AS-Interface emergency shutoff button can be screwed directly onto the machine.

Technical parameters

Slave type: Safety-Slave
AS-Interface specification: V2.1
Required master specification: ≥ V2.0
UL File Number: E198304
MTTFd: 200 a
B10d: 1 E+5
Rated operating voltage: 26.5 ... 31.6 V from AS-Interface
Rated operating current: ≤ 25 mA
Protection class: III
Insulation resistance: min. 100 MΩ
Number/Type: 2 NC Safety function by positive opening in accordance with IEC/EN 60947-5-1 Reset by pulling
Supply: from AS-Interface
Electromagnetic compatibility: Directive 2014/30/EU: EN 62026-2:2013
Electromagnetic compatibility: EN 62026-2:2013
Degree of protection: EN 60529:2000
Electrical safety: EN 60947-5-5:1997+A1:2005
AS-Interface: EN 62026-2:2013
Functional safety: EN 62061:2005 EN 61508 Parts 1-7:2010 NFPA 79:2007 EN 60204-1:2006
Profile: S-0.B.E
IO code: 0
ID code: B
ID1 code: F
ID2 code: E
Data bits (function via AS-Interface): input output
Electromagnetic compatibility: D0: dyn. safety code 1 -
Electromagnetic compatibility: D1: dyn. safety code 1 -
Electromagnetic compatibility: D2: dyn. safety code 2 -
Electromagnetic compatibility: D3: dyn. safety code 2 -
Parameter bits (programmable via AS-i): function
Electromagnetic compatibility: P0: not used
Electromagnetic compatibility: P1: not used
Electromagnetic compatibility: P2: not used
Electromagnetic compatibility: P3: not used
Ambient temperature: -25 ... 55 °C (-13 ... 131 °F) (no freezing)
Storage temperature: -40 ... 70 °C (-40 ... 158 °F)
Relative humidity: 40 ... 85 % , noncondensing
Operating force: Push: 32 N Pull: 21 N Turn: 0.27 Nm Minimum for positive opening operation: 60 Nm
Operating distance: for positive opening operation: min. 4 mm maximal: 4.5 mm
Degree of protection: IP65 Module: IP20
Connection: M12 round connector
Material: Housing: PC
Mass: 195 g
Life span: > 250,000 switching operations

Logistic parameters

ECCN:
Country of Origin: Japan
EAN: 4050143020195
Weight: 0.26 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m