Pepperl+Fuchs 192147

SB4-OR-4XP-4M

Safety control unit

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4, 4 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Operating voltage: 24 V DC, ± 20 %fa

Technical parameters

Operating mode: Start/restart disable, relay monitor, muting operating modes
Safety Integrity Level (SIL): SIL 3
Performance level (PL): PL e
Category: Cat. 4
Mission Time (TM): 20 a
PFHd: 3.5 E-9
B10d: see instruction manuals
Diagnostics indicator: 7-segment display
Function indicator: LED red: OSSD OFF LED green: OSSD ON Yellow LED: start readiness channel 1 - 4 LED yellow: switching state (receiver)
Pre-fault indicator: LED yellow flashing: Indicator lamp channel 1 ... 4
Operating voltage: 24 V DC, ± 20 %
Safety output: 2 relay outputs, force-guided NO-contact
Signal output: 1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltage: 10 V ... 250 V AC/DC
Switching current: min. 10 mA , max. 6 A AC/DC
Functional safety: ISO 13849-1 ; EN 61508 part1-4
Product standard: EN 61496-1
Degree of protection: IP20
Connection: screw terminals , lead cross section 0.2 ... 2 mm2

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m