187124
VBG-PB-K25
AS-Interface gateway
PROFIBUS gatewayfa. The VBG-PB-K25 is a PROFIBUS Gateway in accordance with AS-Interface Specification 3.0 and to IP20. The compact construction makes it particularly suitable for use in the control cabinet. The VBG-PB-K25 is a modular PROFIBUS Slave. This means, that the PROFIBUS configuration tool can be used to determine which data are to be transferred via PROFIBUS. The quantity of data to be transferred via PROFIBUS can be adapted by this means. This gateway supports the acyclic communication of the PROFIBUS DP V1. With the help of this acyclic service a mail box in the gateway for both AS-Interface masters can be addressed, via which all data made available by the AS-Interface/PROFIBUS gateway can be accessed. Address assignment, acceptance of the set configuration, the setting of the PROFIBUS and baud rate are possible via push button. 7 LEDs, mounted on the front, indicate the current status of the AS-Interface network. This gateway can be used to keep the commissioning of the AS-Interface circuit, as well as the test of the connected peripherals, completely separate from the commissioning of the PROFIBUS and the programming. Local operation using the LED display and the 2 buttons enables all the functions to be represented, which are covered by the other gateways via the AS-i Control Tools software. PLC functionality. Optionally the gateway is also available with PLC-functionality. Therefor you can order a code key VAZ-CTR additionally.
| AS-Interface specification: | V3.0 |
| PLC-Functionality: | activateable |
| Earth fault detection: | integrated |
| EMC monitoring: | integrated |
| Diagnostics function: | integrated |
| UL File Number: | E223772 |
| MTTFd: | 105 a at 30 °C |
| Display: | address display, error message LED display, 3 digits, for addressing and error messages |
| LED PROFIBUS: | PROFIBUS master detected; LED green |
| LED AS-i ACTIVE: | AS-Interface operation normal; LED green |
| LED CONFIG ERR: | configuration error; LED red |
| LED PRG ENABLE: | autom. programming; LED green |
| LED POWER: | voltage ON; LED green |
| LED PRJ MODE: | projecting mode active; LED yellow |
| LED U AS-i: | AS-Interface voltage; LED green |
| Switch SET: | Selection and setting of a slave address |
| Button MODE: | Mode selection PRJ-operation/save configuration/cursor |
| Insulation voltage: | ≥ 500 V |
| Rated operating voltage: | from AS-Interface |
| Rated operating current: | ≤ 200 mA from AS-Interface |
| Interface type: | RS-485 |
| Protocol: | PROFIBUS DP V0 and V1 |
| Transfer rate: | 9.6 kBit/s ... 12 MBit/s , Automatic baud rate detection |
| PROFIBUS: | Sub-D interface |
| AS-Interface: | spring terminals, removable |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 62026-2:2013 |
| Electromagnetic compatibility: | EN 61000-6-2, EN 61000-6-4 |
| Degree of protection: | EN 60529:2000 |
| AS-Interface: | EN 62026-2:2013 |
| Shock resistance: | EN 61131-2 |
| Ambient temperature: | 0 ... 55 °C (32 ... 131 °F) |
| Storage temperature: | -25 ... 85 °C (-13 ... 185 °F) |
| Degree of protection: | IP20 |
| Mass: | approx. 460 g |
| Construction type: | Low profile housing , Stainless steel |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.00 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |