Pepperl+Fuchs 183956

IPT1-FP

Read/write station

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

The IPT1-FP read/write station is used in combination with a base which contains the interface for connecting to a computer. Through the choice of base, either serial interfaces or field-bus interfaces may be selected. LF R/W system, fully assembled as configuration and test stationfa. The analysis system is integrated in the device and simplifies the system construction. Protection class IP67 allows the device to be installed directly in the field.

Technical parameters

Operating frequency: 125 kHz
Transfer rate: 2 kBit/s
Operating distance: maximum: 100 mm
UL File Number: E87056
LED green: Power on
LED yellow: IPC detected
LED red: bus fault (when using fieldbus interfaces)
Rated operating voltage: 20 ... 30 V DC , ripple 10 %SS , PELV
Power consumption: max. 5 W , in connection with the base
Galvanic isolation: Operating voltage/interface: functional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff
Mag. Field strength: < 27.3 dBµA/m at 10 m
Physical: Interface type depends on base used
EAC conformity: TR CU 020/2011
Ambient temperature: -25 ... 70 °C (-13 ... 158 °F)
Storage temperature: -40 ... 85 °C (-40 ... 185 °F)
Degree of protection: IP67 according to EN 60529, with base
Material: Housing: PBT

Logistic parameters

ECCN:
Country of Origin: SG
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m