Pepperl+Fuchs 134131

RLK28-8-H-400-IR-Z/31/116

Background suppression sensor

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Background suppression sensor, Universal series with highly versatile fields of use, Resistant against noise: reliable operation under all conditions, Minimal black-white difference through the infrared transmission LED, Programmable time function GAN, GAB, IAB and GAN-IAB as double function, Version for universal voltagesfa

Technical parameters

Detection range: 20 ... 400 mm
Detection range min.: 20 ... 150 mm
Detection range max.: 20 ... 400 mm
Adjustment range: 150 ... 400 mm
Background suppression: max. + 10 % of the upper limit of the detection range
Light source: IRED
Light type: modulated infrared light , 880 nm
Black/White difference (6 %/90 %): < 5 %
Diameter of the light spot: approx. 14 mm at a distance of 400 mm
Angle of divergence: transmitter 2° receiver 2°
Ambient light limit: 50000 Lux
MTTFd: 620 a
Mission Time (TM): 20 a
Diagnostic Coverage (DC): 0 %
Operation indicator: LED green
Function indicator: 2 LEDs yellow ON: object inside the scanning range OFF: object outside the scanning range
Control elements: Sensing range adjuster , Light-on/dark-on changeover switch
Operating voltage: 12 ... 240 V AC/DC
Power consumption: ≤ 3.5 VA
Switching type: light/dark on, switchable (selectable, light/dark switching is only activated if the receiver has 'dark on' selected.)
Signal output: Relay, 1 alternator
Switching voltage: max. 250 V AC/DC
Switching current: max. 2 A
Switching power: DC: max. 50 W AC: max. 500 VA
Switching frequency: 25 Hz
Response time: 20 ms
Timer function: ON delay (GAN), OFF delay (GAB), one shot (IAB), ON delay-one shot (GAN-IAB), ON delay-OFF delay (GAN-GAB), programmable adjustment interval 0.1 ... 10 s
Product standard: EN 60947-5-2
EAC conformity: TR CU 020/2011 TR CU 004/2011
Protection class: II, rated insulation voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit insulated from control circuit in accordance with IEC 61140. Caution! The protection class 2 is only valid when the terminal compartment is closed.
UL approval: E87056 , cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508.
CCC approval: Certified by China Compulsory Certification (CCC)
Ambient temperature: -40 ... 60 °C (-40 ... 140 °F)
Storage temperature: -40 ... 75 °C (-40 ... 167 °F)
Housing width: 25.8 mm
Housing height: 88 mm
Housing depth: 65.5 mm
Degree of protection: IP67
Connection: terminal compartment with 8 spring-loaded terminals for wire cross section 0.5 ... 1.5 mm2, insulation stripping 7.5 ... 8.5 mm, M16 x 1.5 cable gland
Material: Housing: Plastic ABS
Material: Optical face: Plastic pane
Mass: 112 g

Logistic parameters

ECCN:
Country of Origin: VN
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m