Article image 0058398

Dold 0058398

BH5928.92/61 DC24V 0,3-3S

Emergency stop module with time delay BH 5928

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

According to. Performance Level (PL) e and category 4 to EN ISO 13849-1. SIL Claimed Level (SIL CL) 3 to IEC/EN 62061. Safety Integrity Level (SIL 3) to IEC/EN 61508 and IEC/EN 61511. Output: 3 NO or 2 NO, 1 NC instantaneous contacts and. 3 NO release delayed contacts. Single and 2-channel operation. Line fault detection on On-button,, when On-button is connected to S33-S34. Manual restart with button on S33-S34 or automatic restart with, bridge between S13-S14. With or without cross fault monitoring in the E-stop loop. LED indication for supply, channel 1/2 and release delayed contacts. Removable terminal strips. Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),. DIN 46 228-1/-2/-3/-4 or. 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3. Width. BH 5928: 45 mm. BI 5928: 67.5 mm

Downloads

Technical parameters

Function: Emergency stop module with time delay
Also suited as safety gate monitor: +
Cat. / PL according to EN ISO 13849-1: 4/e
SIL CL according to IEC/EN 62061: 3
1- / 2-channel: 1; 2
Output contacts max.: 3 s; 3 sv
Thermal current Ith max.: 5 A
Cross fault detection: +
Nominal voltage DC: +
Nominal voltage AC/DC: +
Approvals: UL
Connection: PS
Width: 45 mm
Type: BH 5928

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.43 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m