Position control for doors / casings on hazardous machinery. Contactless encoded electronic sensor with relay. Category 3 total safety management without an external controller. Suitable for groove profiles and single or double doors

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Level of performance without an external controller: PL = d Level of performance with AWAX controller up to PL = e Safety category without an external controller 3 Safety Integrity Level SIL 2 Cycle before dangerous failure B10d = 2,000,000 at 2A Max. activation distance 8 mm, 3 mm hysteresis Safety contacts/diagnostics 2 x NO 2A/48V redundant / 1 x PNP 250mA (X5) or 1xNF (X5.2) auxiliary Detection encoding mono-code inviolable Indicator LED indicates code recognition Reset automatic (SR version) or Manual (AR version) Attachment 4 tamper-proof M4 screws (optional ref BH4). Suitable for grooved profiles. Screw caps provided. Mounting position 1 Material Polycarbonate Electrical connection 1 M12 connector (X5 version) or 2 M12 connectors (X5.2 version for instant serial connection) Water resistance IP 67/68 Temperature -25°C to +60°C Marking screen printed + serial no. for traceability Certification TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m