Article image EL6910

Beckhoff EL6910

EL6910 | TwinSAFE Logic

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

The EL6910 TwinSAFE Logic can establish up to 212 connections to other TwinSAFE devices. Several EL6910 can be cascaded in a TwinSAFE network with up to 65,535 TwinSAFE devices. The EL6910 EtherCAT Terminal features certified safety function blocks, which are configured according to the application. Safety functions such as emergency stop, safety door monitoring, two-hand control, etc. can thus easily be selected and linked. All blocks can be freely connected among each other and are complemented by operators such as AND, OR, etc.

Technical parameters

Specification: link unit between safe input and output signals
Protocol: TwinSAFE/Safety over EtherCAT
Cycle time: approx. 1 ms/according to project size
Fault response time: ≤ watchdog time (parameterisable)
Current consumption power contacts:
Current consumption E-bus: typ. 160 mA
Installation position: horizontal
Safety standard: EN ISO 13849-1:2015 (Cat. 4, PL e) and EN 61508:2010 (SIL 3)
Weight: approx. 50 g
Protection class: IP 20
Approvals/markings: Overview of TwinSAFE Certifications (PDF)
Download EtherCAT slave information (ESI): ESI config file ELx9xx (ZIP)

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m