Article image EK1300

Beckhoff EK1300

EK1300 | EtherCAT P coupler

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

The EK1300 coupler integrates EtherCAT Terminals (ELxxxx) in the EtherCAT P network. The upper EtherCAT P interface is used to connect the coupler to the network, the lower EtherCAT-P-coded M8 socket is used for optional continuation of the EtherCAT P topology. Since EtherCAT P integrates the power supply and the communication on a single line, an additional power supply for the coupler via the terminal points is no longer required. Depending on the application, the system and sensor supply U. S, or the peripheral voltage for actuators U. P, can be bridged to the power contacts. In addition to the Run LED and the link and activity status, status LEDs indicate the state of the U, and U, voltages, as well as overload and short-circuit events.

Technical parameters

Task within EtherCAT system: coupling of EtherCAT Terminals (ELxxxx) to 100BASE-TX EtherCAT P networks
Data transfer medium: EtherCAT P cable, shielded, to 100BASE-TX EtherCAT P networks
Bus interface: 2 x M8 socket, shielded, screw type, P-coded
Power supply: from EtherCAT P (24 V DC for US and UP)
Total current: from EtherCAT P, max. 3 A per US and UP
Current consumption from US: 40 mA + (∑ E-bus current/4)
Current consumption from UP: typ. 4 mA
Current supply E-bus: 2000 mA
Current rating per port: max. 3 A per US and UP
Electrical isolation: 500 V (power contact/supply voltage/Ethernet)
Operating/storage temperature: 0…+55 °C/-25…+85 °C
Vibration/shock resistance: conforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emission: conforms to EN 61000-6-2/EN 61000-6-4
Protect. class/installation pos.: IP 20/variable
Approvals/markings: CE, UL

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m