Article image BX5200

Beckhoff BX5200

BX5200 | DeviceNet Bus Terminal Controller

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

The BX5200 Bus Terminal Controller has a DeviceNet slave interface. It has automatic baud rate detection up to 500 kbaud and an address selection switch for address assignment. Up to 512 byte of input and 512 byte of output can be exchanged with the controller.

Technical parameters

Programming: TwinCAT (via programming interface or fieldbus)
Program memory: 256 kbytes
Data memory: 256 kbytes
Remanent data: 2 kbytes
Persistent data: 1 kbyte
Runtime system: 1 PLC task
PLC cycle time: approx. 1 ms for 1,000 instructions (without I/O cycle, K-bus)
Programming languages: IEC 61131-3 (IL, LD, FBD, SFC, ST)
Online change: yes
Up/down load code: yes/yes

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m