Article image 2619130000

Weidmueller 2619130000

VPU AC I 2 440/25 LCF

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: VPU AC I 2 440/25 LCF
Order No.: 2619130000
GTIN (EAN): 4050118633986
Qty.: 1 pc(s).
Width: 72 mm
Width (inches): 2.835 inch
Height: 99 mm
Height (inches): 3.898 inch
Depth: 93 mm
Depth (inches): 3.661 inch
Net weight: 25 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 85 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...85 °C
Storage temperature: -40 °C...85 °C
MTBF: 15 Years
Altitude: ≤ 2000 m
Altitude: ≤ 2000 m
Colour: black
Design: Installation housing; 4TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20 in installed state
Rail: TS 35
Segment: Power distribution
Suitable for: Count-in installation (leakage current free)
UL 94 flammability rating: V-0
Version: Surge protection
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 400 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 440 V
Low voltage network: Single-phase, TN, TN-S
Discharge current In (8/20µs) wire-PE: 25 kA
Discharge current Imax (8/20µs) wire-PE: 100 kA
Lightning test current Iimp (10/350 µs) (L-PE): 25 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: 250 A gL (if back up fuse > 250 A)
Short-circuit current rating ISCCR: 50 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11, EN 60068-2-27:2009, EN 60068-2-64:2008, EN 60068-2-6:2008
Energy coordination (≤10 m): Type I, Type II, Type III
Protection level UP (typ.): ≤ 2.5 kV
Protection level Up at IN (L/N-PE): ≤ 2.5 kV
Leakage current at Un: 5 µA
Temporary surge voltage (over-voltage) - TOV: 762 V
Number of poles: 2
Rated load current IL: 100 A
Requirements category acc. to IEC 61643-11: Type I, Type II
Requirements class, acc. to EN 61643-11: T1, T2
Response time: ≤ 25 ns
Signalling contact: No
Suitable for: Count-in installation (leakage current free)
Wire connection method: Screw connection
Type of connection: Screw connection
Stripping length, rated connection: 13 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 6 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 6 mm²
Wire cross-section, solid, max.: 35 mm²
Wire connection cross-section, finely stranded, min.: 6 mm²
Wire connection cross section, finely stranded, max.: 35 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 35 mm²
Connection cross-section, stranded, min.: 6 mm²
Connection cross-section, stranded, max.: 35 mm²
Product information: For use in DC applications, please use the fuse of SIBA Type NH2XL aR/aSF DC 1500 V
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-22
ROHS: Conform
Type: VPU AC I 2 440/25 LCF
Order No.: 2619130000
GTIN (EAN): 4050118633986
Qty.: 1 pc(s).
Width: 72 mm
Width (inches): 2.835 inch
Height: 99 mm
Height (inches): 3.898 inch
Depth: 93 mm
Depth (inches): 3.661 inch
Net weight: 25 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 85 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...85 °C
Storage temperature: -40 °C...85 °C
MTBF: 15 Years
Altitude: ≤ 2000 m
Altitude: ≤ 2000 m
Colour: black
Design: Installation housing; 4TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20 in installed state
Rail: TS 35
Segment: Power distribution
Suitable for: Count-in installation (leakage current free)
UL 94 flammability rating: V-0
Version: Surge protection
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 400 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 440 V
Low voltage network: Single-phase, TN, TN-S
Discharge current In (8/20µs) wire-PE: 25 kA
Discharge current Imax (8/20µs) wire-PE: 100 kA
Lightning test current Iimp (10/350 µs) (L-PE): 25 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: 250 A gL (if back up fuse > 250 A)
Short-circuit current rating ISCCR: 50 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11, EN 60068-2-27:2009, EN 60068-2-64:2008, EN 60068-2-6:2008
Energy coordination (≤10 m): Type I, Type II, Type III
Protection level UP (typ.): ≤ 2.5 kV
Protection level Up at IN (L/N-PE): ≤ 2.5 kV
Leakage current at Un: 5 µA
Temporary surge voltage (over-voltage) - TOV: 762 V
Number of poles: 2
Rated load current IL: 100 A
Requirements category acc. to IEC 61643-11: Type I, Type II
Requirements class, acc. to EN 61643-11: T1, T2
Response time: ≤ 25 ns
Signalling contact: No
Suitable for: Count-in installation (leakage current free)
Wire connection method: Screw connection
Type of connection: Screw connection
Stripping length, rated connection: 13 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 6 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 6 mm²
Wire cross-section, solid, max.: 35 mm²
Wire connection cross-section, finely stranded, min.: 6 mm²
Wire connection cross section, finely stranded, max.: 35 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 35 mm²
Connection cross-section, stranded, min.: 6 mm²
Connection cross-section, stranded, max.: 35 mm²
Product information: For use in DC applications, please use the fuse of SIBA Type NH2XL aR/aSF DC 1500 V
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-22
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.692 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m