Article image 2602580000

Weidmueller 2602580000

ENERGY ANALYSER 550-24

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: ENERGY ANALYSER 550-24
Order No.: 2602580000
GTIN (EAN): 4050118655841
Qty.: 1 pc(s).
Width: 144
Width (inches): 5.669 inch
Height: 144 mm
Height (inches): 5.669 inch
Depth: 81 mm
Depth (inches): 3.189 inch
Net weight: 1,080 g
Humidity: 5...95 %, no condensation
Operating temperature, max.: 55 °C
Operating temperature, min.: -10 °C
Storage temperature, max.: 70 °C
Storage temperature, min.: -25 °C
Operating temperature: -10 °C...55 °C
Storage temperature: -25 °C...70 °C
REACH SVHC: Lead 7439-92-1
Current-measuring channels: 4 + 2
Distortion factor THD-I in %: Yes
Harmonics, per order / current: 1.-63.
Measuring accuracy for current: 0.2 %
Rated current: 1 / 5 A
Residual current measuring: Yes
Distortion factor THD-U in %: Yes
Four-wire system: Yes
Harmonics, per order / voltage: 1.-63.
Measurement range, voltage L-L, AC: 720 V
Measurement range, voltage L-N, AC: 417 V
Measuring accuracy for voltage: 0.1 %
Quadrants: 4
Three-wire system: Yes
Interface: RS485: 9.6 – 921.6 kbps, Profibus DP, Ethernet, Web server/e-mail
Protocol: Modbus RTU, Modbus-Gateway, Modbus TCP/IP, Modbus RTU over Ethernet, SNMP, Profibus DP V0, BACnet (optional)
Number of digital inputs: 2
Number of digital outputs: 2
Number of pulse outputs: 2
Temperature input: Yes
Memory; minimum and maximum values: Yes
Memory size: 256 MB
Number of memory values: 10,000 k
Update interval register: 200 ms
Min. memory recording interval: 1 s
Software: ecoExplorer go®
Integrated logic: Yes
Standards: DIN EN 61326-1, DIN EN 61000-4-2, DIN EN 61000-4-3, DIN EN 61000-4-4, DIN EN 61000-4-5, DIN EN 61000-4-6, EN 61000-4-11, EN 55011, IEC 61010-1, IEC 61010-2-030, DIN EN 61000-4-8
Measurement range, voltage L-N, AC: 417 V
Measurement range, voltage L-L, AC: 720 V
Surge voltage category: 600 V CAT III
Voltage supply: 48…110 V AC, 24…150 V DC
Three-wire system: Yes
Four-wire system: Yes
Quadrants: 4
Sampling frequency 50/60 Hz: 20 kHz
Continuous measurements: Yes
Effective value from the period (50/60 Hz): 10 / 12
Measurement result per second: 5
Residual current measuring: Yes
Measuring accuracy for voltage: 0.1 %
Measuring accuracy for current: 0.2 %
Measurement accuracy for active energy (kWh, …/5 A): Class 0.2S
Operating-hours counter: Yes
Weekly time switch: Yes
Current-measuring channels: 4 + 2
Clock: Yes
Bimetal function: Yes
Harmonics, per order / voltage: 1.-63.
Harmonics, per order / current: 1.-63.
Distortion factor THD-U in %: Yes
Distortion factor THD-I in %: Yes
Unbalanced: Yes
Positive, negative and zero system: Yes
Brief interruptions: Yes
Sequence-of-events recorder function: Yes
Surge voltage category: 600 V CAT III
ETIM 6.0: EC002301
ETIM 7.0: EC002301
eClass 9.0: 27-14-23-30
eClass 9.1: 27-21-03-01
eClass 10.0: 27-14-23-30
ROHS: Conform
Type: ENERGY ANALYSER 550-24
Order No.: 2602580000
GTIN (EAN): 4050118655841
Qty.: 1 pc(s).
Width: 144
Width (inches): 5.669 inch
Height: 144 mm
Height (inches): 5.669 inch
Depth: 81 mm
Depth (inches): 3.189 inch
Net weight: 1,080 g
Humidity: 5...95 %, no condensation
Operating temperature, max.: 55 °C
Operating temperature, min.: -10 °C
Storage temperature, max.: 70 °C
Storage temperature, min.: -25 °C
Operating temperature: -10 °C...55 °C
Storage temperature: -25 °C...70 °C
REACH SVHC: Lead 7439-92-1
Current-measuring channels: 4 + 2
Distortion factor THD-I in %: Yes
Harmonics, per order / current: 1.-63.
Measuring accuracy for current: 0.2 %
Rated current: 1 / 5 A
Residual current measuring: Yes
Distortion factor THD-U in %: Yes
Four-wire system: Yes
Harmonics, per order / voltage: 1.-63.
Measurement range, voltage L-L, AC: 720 V
Measurement range, voltage L-N, AC: 417 V
Measuring accuracy for voltage: 0.1 %
Quadrants: 4
Three-wire system: Yes
Interface: RS485: 9.6 – 921.6 kbps, Profibus DP, Ethernet, Web server/e-mail
Protocol: Modbus RTU, Modbus-Gateway, Modbus TCP/IP, Modbus RTU over Ethernet, SNMP, Profibus DP V0, BACnet (optional)
Number of digital inputs: 2
Number of digital outputs: 2
Number of pulse outputs: 2
Temperature input: Yes
Memory; minimum and maximum values: Yes
Memory size: 256 MB
Number of memory values: 10,000 k
Update interval register: 200 ms
Min. memory recording interval: 1 s
Software: ecoExplorer go®
Integrated logic: Yes
Standards: DIN EN 61326-1, DIN EN 61000-4-2, DIN EN 61000-4-3, DIN EN 61000-4-4, DIN EN 61000-4-5, DIN EN 61000-4-6, EN 61000-4-11, EN 55011, IEC 61010-1, IEC 61010-2-030, DIN EN 61000-4-8
Measurement range, voltage L-N, AC: 417 V
Measurement range, voltage L-L, AC: 720 V
Surge voltage category: 600 V CAT III
Voltage supply: 48…110 V AC, 24…150 V DC
Three-wire system: Yes
Four-wire system: Yes
Quadrants: 4
Sampling frequency 50/60 Hz: 20 kHz
Continuous measurements: Yes
Effective value from the period (50/60 Hz): 10 / 12
Measurement result per second: 5
Residual current measuring: Yes
Measuring accuracy for voltage: 0.1 %
Measuring accuracy for current: 0.2 %
Measurement accuracy for active energy (kWh, …/5 A): Class 0.2S
Operating-hours counter: Yes
Weekly time switch: Yes
Current-measuring channels: 4 + 2
Clock: Yes
Bimetal function: Yes
Harmonics, per order / voltage: 1.-63.
Harmonics, per order / current: 1.-63.
Distortion factor THD-U in %: Yes
Distortion factor THD-I in %: Yes
Unbalanced: Yes
Positive, negative and zero system: Yes
Brief interruptions: Yes
Sequence-of-events recorder function: Yes
Surge voltage category: 600 V CAT III
ETIM 6.0: EC002301
ETIM 7.0: EC002301
eClass 9.0: 27-14-23-30
eClass 9.1: 27-21-03-01
eClass 10.0: 27-14-23-30
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 1.275 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m