2539970000
A2T 4
| Type: | A2T 4 |
| Order No.: | 2539970000 |
| Version: | Double-tier terminal, PUSH IN, 4 mm², 800 V, 32 A, dark beige |
| GTIN (EAN): | 4050118551860 |
| Qty.: | 50 pc(s). |
| Width: | 6.1 mm |
| Width (inches): | 0.24 inch |
| Height: | 100 mm |
| Height (inches): | 3.937 inch |
| Depth: | 53.5 mm |
| Depth (inches): | 2.106 inch |
| Depth including DIN rail: | 54.5 mm |
| Net weight: | 20.416 g |
| Storage temperature, max.: | 40 °C |
| Storage temperature, min.: | 10 °C |
| Storage temperature: | 10 °C...40 °C |
| Continuous operating temp., min.: | -60 °C |
| Continuous operating temp., max.: | 130 °C |
| Material: | Wemid |
| Colour: | dark beige |
| Colour of operational elements: | orange |
| UL 94 flammability rating: | V-0 |
| Certificate No. (ATEX): | TUEV16ATEX7909U |
| Certificate No. (IECEX): | IECEXTUR16.0036U |
| Max. voltage (ATEX): | 550 V |
| Current (ATEX): | 25 A |
| Wire cross section max. (ATEX): | 4 mm² |
| Max. voltage (IECEX): | 550 V |
| Current (IECEX): | 25 A |
| Wire cross section max. (IECEX): | 4 mm² |
| End cover plate required: | Yes |
| Number of potentials: | 2 |
| Number of levels: | 2 |
| Number of clamping points per level: | 2 |
| Number of potentials per tier: | 1 |
| Levels cross-connected internally: | No |
| PE connection: | No |
| Rail: | TS 35 |
| N-function: | No |
| PE function: | No |
| PEN function: | No |
| Installation advice: | Rail |
| Open sides: | right |
| Snap-on: | No |
| Type of fixing: | Snap-on |
| Type of mounting: | TS 35 |
| With snap-in pegs: | No |
| Blade size: | 0.6 x 3.5 mm |
| Clamping range, max.: | 4 mm² |
| Clamping range, min.: | 0.14 mm² |
| Connection cross-section, stranded, max.: | 4 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection direction: | top |
| Gauge to IEC 60947-1: | A4 |
| Number of connections: | 4 |
| Stripping length: | 12 mm |
| Twin wire-end ferrules, max.: | 1.5 mm² |
| Twin wire-end ferrules, min.: | 0.5 mm² |
| Type of connection: | PUSH IN |
| Wire connection cross section AWG, max.: | AWG 12 |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section, finely stranded, max.: | 4 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.: | 4 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.: | 0.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 4 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.5 mm² |
| Wire connection cross-section, solid core, max.: | 4 mm² |
| Wire connection cross-section, solid core, min.: | 0.5 mm² |
| Rated cross-section: | 4 mm² |
| Rated voltage: | 800 V |
| Rated current: | 32 A |
| Current at maximum wires: | 32 A |
| Standards: | IEC 60947-7-1 |
| Volume resistance according to IEC 60947-7-x: | 1 mΩ |
| Power loss in accordance with IEC 60947-7-x: | 2.04 W |
| Rated impulse withstand voltage: | 8 kV |
| Pollution severity: | 3 |
| Surge voltage category: | III |
| Certificate No. (cURus): | E60693 |
| Conductor size Factory wiring max. (cURus): | 10 AWG |
| Conductor size Factory wiring min. (cURus): | 26 AWG |
| Conductor size Field wiring max. (cURus): | 10 AWG |
| Conductor size Field wiring min. (cURus): | 26 AWG |
| Current size B (cURus): | 30 A |
| Current size C (cURus): | 30 A |
| Current size D (cURus): | 5 A |
| Voltage size B (cURus): | 600 V |
| Voltage size C (cURus): | 600 V |
| Voltage size D (cURus): | 600 V |
| ETIM 6.0: | EC000897 |
| ETIM 7.0: | EC000897 |
| eClass 9.0: | 27-14-11-20 |
| eClass 9.1: | 27-14-11-20 |
| eClass 10.0: | 27-14-11-20 |
| Type: | A2T 4 |
| Order No.: | 2539970000 |
| Version: | Double-tier terminal, PUSH IN, 4 mm², 800 V, 32 A, dark beige |
| GTIN (EAN): | 4050118551860 |
| Qty.: | 50 pc(s). |
| Width: | 6.1 mm |
| Width (inches): | 0.24 inch |
| Height: | 100 mm |
| Height (inches): | 3.937 inch |
| Depth: | 53.5 mm |
| Depth (inches): | 2.106 inch |
| Depth including DIN rail: | 54.5 mm |
| Net weight: | 20.416 g |
| Storage temperature, max.: | 40 °C |
| Storage temperature, min.: | 10 °C |
| Storage temperature: | 10 °C...40 °C |
| Continuous operating temp., min.: | -60 °C |
| Continuous operating temp., max.: | 130 °C |
| Material: | Wemid |
| Colour: | dark beige |
| Colour of operational elements: | orange |
| UL 94 flammability rating: | V-0 |
| Certificate No. (ATEX): | TUEV16ATEX7909U |
| Certificate No. (IECEX): | IECEXTUR16.0036U |
| Max. voltage (ATEX): | 550 V |
| Current (ATEX): | 25 A |
| Wire cross section max. (ATEX): | 4 mm² |
| Max. voltage (IECEX): | 550 V |
| Current (IECEX): | 25 A |
| Wire cross section max. (IECEX): | 4 mm² |
| End cover plate required: | Yes |
| Number of potentials: | 2 |
| Number of levels: | 2 |
| Number of clamping points per level: | 2 |
| Number of potentials per tier: | 1 |
| Levels cross-connected internally: | No |
| PE connection: | No |
| Rail: | TS 35 |
| N-function: | No |
| PE function: | No |
| PEN function: | No |
| Installation advice: | Rail |
| Open sides: | right |
| Snap-on: | No |
| Type of fixing: | Snap-on |
| Type of mounting: | TS 35 |
| With snap-in pegs: | No |
| Blade size: | 0.6 x 3.5 mm |
| Clamping range, max.: | 4 mm² |
| Clamping range, min.: | 0.14 mm² |
| Connection cross-section, stranded, max.: | 4 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection direction: | top |
| Gauge to IEC 60947-1: | A4 |
| Number of connections: | 4 |
| Stripping length: | 12 mm |
| Twin wire-end ferrules, max.: | 1.5 mm² |
| Twin wire-end ferrules, min.: | 0.5 mm² |
| Type of connection: | PUSH IN |
| Wire connection cross section AWG, max.: | AWG 12 |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section, finely stranded, max.: | 4 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.: | 4 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.: | 0.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 4 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.5 mm² |
| Wire connection cross-section, solid core, max.: | 4 mm² |
| Wire connection cross-section, solid core, min.: | 0.5 mm² |
| Rated cross-section: | 4 mm² |
| Rated voltage: | 800 V |
| Rated current: | 32 A |
| Current at maximum wires: | 32 A |
| Standards: | IEC 60947-7-1 |
| Volume resistance according to IEC 60947-7-x: | 1 mΩ |
| Power loss in accordance with IEC 60947-7-x: | 2.04 W |
| Rated impulse withstand voltage: | 8 kV |
| Pollution severity: | 3 |
| Surge voltage category: | III |
| Certificate No. (cURus): | E60693 |
| Conductor size Factory wiring max. (cURus): | 10 AWG |
| Conductor size Factory wiring min. (cURus): | 26 AWG |
| Conductor size Field wiring max. (cURus): | 10 AWG |
| Conductor size Field wiring min. (cURus): | 26 AWG |
| Current size B (cURus): | 30 A |
| Current size C (cURus): | 30 A |
| Current size D (cURus): | 5 A |
| Voltage size B (cURus): | 600 V |
| Voltage size C (cURus): | 600 V |
| Voltage size D (cURus): | 600 V |
| ETIM 6.0: | EC000897 |
| ETIM 7.0: | EC000897 |
| eClass 9.0: | 27-14-11-20 |
| eClass 9.1: | 27-14-11-20 |
| eClass 10.0: | 27-14-11-20 |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.022 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |