2456530000
UR20-8DIO-P-3W-DIAG
| Type: | UR20-8DIO-P-3W-DIAG |
| Order No.: | 2456530000 |
| Version: | Remote I/O module, IP20, Digital signals, Input, Output, 8-channel |
| GTIN (EAN): | 4050118471694 |
| Qty.: | 1 pc(s). |
| Width: | 11.5 |
| Width (inches): | 0.453 inch |
| Height: | 120 mm |
| Height (inches): | 4.724 inch |
| Depth: | 76 mm |
| Depth (inches): | 2.992 inch |
| Mounting dimension - height: | 128 mm |
| Net weight: | 83 g |
| Operating temperature, max.: | 60 °C |
| Operating temperature, min.: | -20 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -20 °C ... +60 °C |
| Storage temperature: | -40 °C ... +85 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Input filter: | Input delay adjustable from 0 to 40 ms |
| Module diagnosis: | Yes |
| Number of digital inputs: | 8 |
| Reverse polarity protection: | No, Input voltage below -10 V can destroy the module |
| Sensor connection: | 2-wire, 3-wire |
| Sensor supply: | ≥ 0.3 A per connector, limited electronically |
| Type: | PNP switched |
| Actuator connection: | 2-wire, 3-wire |
| Feedback-free: | Yes |
| Inductive load (DC13): | 0.2 Hz |
| Lamp load (12 W): | 10 Hz |
| Module diagnosis: | Yes |
| Number of digital outputs: | 8 |
| Output current per channel, max.: | 0.5 A |
| Output current per module, max.: | 4 A |
| Resistive load (min. 47 Ω): | 1 kHz |
| Response time of the protective circuit (current limiting): | < 100μs |
| Short-circuit-proof: | Yes |
| Switch-off energy (inductive): | < 150 mJ / channel |
| Type: | PNP switched |
| Type of connection: | PUSH IN |
| Wire connection cross section, finely stranded, max.: | 1.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.14 mm² |
| Wire cross-section, finely stranded, max. (AWG): | AWG 16 |
| Wire cross-section, finely stranded, min. (AWG): | AWG 26 |
| Wire cross-section, solid, max.: | 1.5 mm² |
| Wire cross-section, solid, max. (AWG): | AWG 16 |
| Wire cross-section, solid, min.: | 0.14 mm² |
| Wire cross-section, solid, min. (AWG): | AWG 26 |
| Air humidity (operation): | 10% to 95%, non-condensing as per DIN EN 61131-2 |
| Air humidity (storage): | 10% to 95%, non-condensing as per DIN EN 61131-2 |
| Air humidity (transport): | 10% to 95%, non-condensing as per DIN EN 61131-2 |
| Air pressure (operation): | ≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2 |
| Air pressure (storage): | 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2 |
| Air pressure (transport): | 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2 |
| Pollution severity: | 2 |
| Shock: | 15 g over 11 ms, half sinus wave, acc. to IEC 60068-2-27 |
| Surge voltage category: | II |
| Test voltage: | 500 V |
| UL 94 flammability rating: | V-0 |
| Vibration resistance: | 5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6 |
| Current consumption from IIN (power segment of the field bus coupler), typ.: | 8 mA |
| Current consumption from IIN (the respective power segment): | 8 mA |
| Current consumption from IOUT (the respective power segment): | 32 mA + I-Last |
| Reverse polarity protection: | No, Input voltage below -10 V can destroy the module |
| Voltage supply: | 24 V DC +20 %/ -15 %, via the system bus |
| Field bus protocol: | CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus/TCP, PROFINET IRT, PROFIBUS DP-V1, POWERLINK |
| Galvanic isolation: | 500 V DC between the current paths |
| Interface: | u-remote system bus |
| Possible connection: | 2-wire, 3-wire |
| Transmission speed of system bus, max.: | 48 Mbit |
| ETIM 6.0: | EC001597 |
| ETIM 7.0: | EC001597 |
| eClass 9.0: | 27-24-26-02 |
| eClass 9.1: | 27-24-26-02 |
| eClass 10.0: | 27-24-26-02 |
| Type: | UR20-8DIO-P-3W-DIAG |
| Order No.: | 2456530000 |
| Version: | Remote I/O module, IP20, Digital signals, Input, Output, 8-channel |
| GTIN (EAN): | 4050118471694 |
| Qty.: | 1 pc(s). |
| Width: | 11.5 |
| Width (inches): | 0.453 inch |
| Height: | 120 mm |
| Height (inches): | 4.724 inch |
| Depth: | 76 mm |
| Depth (inches): | 2.992 inch |
| Mounting dimension - height: | 128 mm |
| Net weight: | 83 g |
| Operating temperature, max.: | 60 °C |
| Operating temperature, min.: | -20 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -20 °C ... +60 °C |
| Storage temperature: | -40 °C ... +85 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Input filter: | Input delay adjustable from 0 to 40 ms |
| Module diagnosis: | Yes |
| Number of digital inputs: | 8 |
| Reverse polarity protection: | No, Input voltage below -10 V can destroy the module |
| Sensor connection: | 2-wire, 3-wire |
| Sensor supply: | ≥ 0.3 A per connector, limited electronically |
| Type: | PNP switched |
| Actuator connection: | 2-wire, 3-wire |
| Feedback-free: | Yes |
| Inductive load (DC13): | 0.2 Hz |
| Lamp load (12 W): | 10 Hz |
| Module diagnosis: | Yes |
| Number of digital outputs: | 8 |
| Output current per channel, max.: | 0.5 A |
| Output current per module, max.: | 4 A |
| Resistive load (min. 47 Ω): | 1 kHz |
| Response time of the protective circuit (current limiting): | < 100μs |
| Short-circuit-proof: | Yes |
| Switch-off energy (inductive): | < 150 mJ / channel |
| Type: | PNP switched |
| Type of connection: | PUSH IN |
| Wire connection cross section, finely stranded, max.: | 1.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.14 mm² |
| Wire cross-section, finely stranded, max. (AWG): | AWG 16 |
| Wire cross-section, finely stranded, min. (AWG): | AWG 26 |
| Wire cross-section, solid, max.: | 1.5 mm² |
| Wire cross-section, solid, max. (AWG): | AWG 16 |
| Wire cross-section, solid, min.: | 0.14 mm² |
| Wire cross-section, solid, min. (AWG): | AWG 26 |
| Air humidity (operation): | 10% to 95%, non-condensing as per DIN EN 61131-2 |
| Air humidity (storage): | 10% to 95%, non-condensing as per DIN EN 61131-2 |
| Air humidity (transport): | 10% to 95%, non-condensing as per DIN EN 61131-2 |
| Air pressure (operation): | ≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2 |
| Air pressure (storage): | 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2 |
| Air pressure (transport): | 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2 |
| Pollution severity: | 2 |
| Shock: | 15 g over 11 ms, half sinus wave, acc. to IEC 60068-2-27 |
| Surge voltage category: | II |
| Test voltage: | 500 V |
| UL 94 flammability rating: | V-0 |
| Vibration resistance: | 5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6 |
| Current consumption from IIN (power segment of the field bus coupler), typ.: | 8 mA |
| Current consumption from IIN (the respective power segment): | 8 mA |
| Current consumption from IOUT (the respective power segment): | 32 mA + I-Last |
| Reverse polarity protection: | No, Input voltage below -10 V can destroy the module |
| Voltage supply: | 24 V DC +20 %/ -15 %, via the system bus |
| Field bus protocol: | CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus/TCP, PROFINET IRT, PROFIBUS DP-V1, POWERLINK |
| Galvanic isolation: | 500 V DC between the current paths |
| Interface: | u-remote system bus |
| Possible connection: | 2-wire, 3-wire |
| Transmission speed of system bus, max.: | 48 Mbit |
| ETIM 6.0: | EC001597 |
| ETIM 7.0: | EC001597 |
| eClass 9.0: | 27-24-26-02 |
| eClass 9.1: | 27-24-26-02 |
| eClass 10.0: | 27-24-26-02 |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.104 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |