2456190000
ACT20X-2HTI-2SAO-P
Type: | ACT20X-2HTI-2SAO-P |
Order No.: | 2456190000 |
Version: | EX signal isolating converter, Ex-input: I,ϑ, Safe-output: 4-20mA, 2-channel |
GTIN (EAN): | 4050118471588 |
Qty.: | 1 pc(s). |
Width: | 22.5 mm |
Width (inches): | 0.886 inch |
Height: | 127.3 mm |
Height (inches): | 5.012 inch |
Depth: | 114.6 mm |
Depth (inches): | 4.512 inch |
Net weight: | 180 g |
Humidity: | 0...95 % (no condensation) |
Operating temperature, max.: | 60 °C |
Operating temperature, min.: | -20 °C |
Storage temperature, max.: | 85 °C |
Storage temperature, min.: | -20 °C |
Operating temperature: | -20 °C...60 °C |
Storage temperature: | -20 °C...85 °C |
MTBF: | 111 Years |
SIL in compliance with IEC 61508: | 2 |
REACH SVHC: | Lead 7439-92-1 |
Input current: | 0...20 mA, 4…20mA |
Input resistance, current: | 20 Ω + PTC 50 Ω |
Line resistance in measuring circuit: | ≤ 50 Ω |
Sensor: | RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710 |
Temperature input range: | Configurable |
Type: | intrinsically safe circuit, RTD, TC, DC (mA) |
Type: | active (as current source) or passive (as current sink) |
Influence of load resistance: | ≤ 0.01% of span / 100 Ω |
Output signal limit: | 3.8…20.5 mA / 0…20.5 mA (dependent on range) |
Output current: | 0…23 mA, configurable: 0…20 / 4…20 / 20…0 / 20…4 mA, configurable downscale (3.5 mA) ⁄ upscale (23 mA) @ error |
Load impedance current: | ≤ 600 Ω |
Alarm function: | Line interruption at the input, Short circuit at input, No supply voltage, Device error |
Type: | Relay, 1 NC (voltage-free) |
Continuous current: | ≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2) |
Configuration: | With FDT/DTM software |
Voltage supply: | 19.2…31.2 V DC |
Type of connection: | PUSH IN |
Power consumption: | ≤ 1.4 W |
Step response time: | ≤ 400 ms (with current), ≤ 1 s (with temperature) |
Protection degree: | IP20 |
Humidity: | 0...95 % (no condensation) |
EMC standards: | DIN EN 61326, NE 21 |
Insulation voltage: | 2.6 kV (input / output) |
Rated voltage: | 300 V |
Voltage U0: | 8.7 V DC |
Current I0: | 18.4 mA |
Power P0: | 40 mW |
Marking: | II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I |
Installation location: | Device installed in safe area, zone 2 |
Demand mode: | High |
Demand rate: | 3,000 s |
Demand response time: | Signal input: < 0.5 s (opto output), Temperature input: < 1.1 s (opto output) |
Description of the "safe state": | analogue Output ≤ 3.6 mA or output ≥ 21 mA |
Device type: | B |
Diagnostic test interval: | 30 s |
Hardware fault tolerance (HFT): | 0 |
Mean Time To Repair (MTTR): | 24 h |
Safe Failure Fraction (SFF): | 90 % |
Tproof: | 3 Years |
Total failure rate for dangerous detected failures (λDD): | 367 FIT |
Total failure rate for dangerous undetected failures (λDU): | 61 FIT |
Total failure rate for safe detected failures (λSD): | 0 FIT |
Total failure rate for safe undetected failures (λSU): | 234 FIT |
Safety category: | SIL 2 |
Type of connection: | PUSH IN |
Wire connection cross section AWG, min.: | AWG 26 |
Wire connection cross section AWG, max.: | AWG 14 |
Wire cross-section, solid, min.: | 0.2 mm² |
Wire cross-section, solid, max.: | 2.5 mm² |
Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
Wire connection cross section, finely stranded, max.: | 2.5 mm² |
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
ETIM 6.0: | EC002919 |
ETIM 7.0: | EC002919 |
eClass 9.0: | 27-21-01-29 |
eClass 9.1: | 27-21-01-29 |
eClass 10.0: | 27-21-01-29 |
ROHS: | Conform |
Type: | ACT20X-2HTI-2SAO-P |
Order No.: | 2456190000 |
Version: | EX signal isolating converter, Ex-input: I,ϑ, Safe-output: 4-20mA, 2-channel |
GTIN (EAN): | 4050118471588 |
Qty.: | 1 pc(s). |
Width: | 22.5 mm |
Width (inches): | 0.886 inch |
Height: | 127.3 mm |
Height (inches): | 5.012 inch |
Depth: | 114.6 mm |
Depth (inches): | 4.512 inch |
Net weight: | 180 g |
Humidity: | 0...95 % (no condensation) |
Operating temperature, max.: | 60 °C |
Operating temperature, min.: | -20 °C |
Storage temperature, max.: | 85 °C |
Storage temperature, min.: | -20 °C |
Operating temperature: | -20 °C...60 °C |
Storage temperature: | -20 °C...85 °C |
MTBF: | 111 Years |
SIL in compliance with IEC 61508: | 2 |
REACH SVHC: | Lead 7439-92-1 |
Input current: | 0...20 mA, 4…20mA |
Input resistance, current: | 20 Ω + PTC 50 Ω |
Line resistance in measuring circuit: | ≤ 50 Ω |
Sensor: | RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710 |
Temperature input range: | Configurable |
Type: | intrinsically safe circuit, RTD, TC, DC (mA) |
Type: | active (as current source) or passive (as current sink) |
Influence of load resistance: | ≤ 0.01% of span / 100 Ω |
Output signal limit: | 3.8…20.5 mA / 0…20.5 mA (dependent on range) |
Output current: | 0…23 mA, configurable: 0…20 / 4…20 / 20…0 / 20…4 mA, configurable downscale (3.5 mA) ⁄ upscale (23 mA) @ error |
Load impedance current: | ≤ 600 Ω |
Alarm function: | Line interruption at the input, Short circuit at input, No supply voltage, Device error |
Type: | Relay, 1 NC (voltage-free) |
Continuous current: | ≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2) |
Configuration: | With FDT/DTM software |
Voltage supply: | 19.2…31.2 V DC |
Type of connection: | PUSH IN |
Power consumption: | ≤ 1.4 W |
Step response time: | ≤ 400 ms (with current), ≤ 1 s (with temperature) |
Protection degree: | IP20 |
Humidity: | 0...95 % (no condensation) |
EMC standards: | DIN EN 61326, NE 21 |
Insulation voltage: | 2.6 kV (input / output) |
Rated voltage: | 300 V |
Voltage U0: | 8.7 V DC |
Current I0: | 18.4 mA |
Power P0: | 40 mW |
Marking: | II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I |
Installation location: | Device installed in safe area, zone 2 |
Demand mode: | High |
Demand rate: | 3,000 s |
Demand response time: | Signal input: < 0.5 s (opto output), Temperature input: < 1.1 s (opto output) |
Description of the "safe state": | analogue Output ≤ 3.6 mA or output ≥ 21 mA |
Device type: | B |
Diagnostic test interval: | 30 s |
Hardware fault tolerance (HFT): | 0 |
Mean Time To Repair (MTTR): | 24 h |
Safe Failure Fraction (SFF): | 90 % |
Tproof: | 3 Years |
Total failure rate for dangerous detected failures (λDD): | 367 FIT |
Total failure rate for dangerous undetected failures (λDU): | 61 FIT |
Total failure rate for safe detected failures (λSD): | 0 FIT |
Total failure rate for safe undetected failures (λSU): | 234 FIT |
Safety category: | SIL 2 |
Type of connection: | PUSH IN |
Wire connection cross section AWG, min.: | AWG 26 |
Wire connection cross section AWG, max.: | AWG 14 |
Wire cross-section, solid, min.: | 0.2 mm² |
Wire cross-section, solid, max.: | 2.5 mm² |
Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
Wire connection cross section, finely stranded, max.: | 2.5 mm² |
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
ETIM 6.0: | EC002919 |
ETIM 7.0: | EC002919 |
eClass 9.0: | 27-21-01-29 |
eClass 9.1: | 27-21-01-29 |
eClass 10.0: | 27-21-01-29 |
ROHS: | Conform |
ECCN: | |
Country of Origin: | |
EAN: | |
Weight: | 0.204 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |