Technical parameters

Type: ACT20X-2HAI-2SAO-P
Order No.: 2456150000
Version: EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, 2-channel
GTIN (EAN): 4050118471281
Qty.: 1 pc(s).
Width: 22.5 mm
Width (inches): 0.886 inch
Height: 127.3 mm
Height (inches): 5.012 inch
Depth: 114.6 mm
Depth (inches): 4.512 inch
Net weight: 212 g
Humidity: 0...95 % (no condensation)
Operating temperature, max.: 60 °C
Operating temperature, min.: -20 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -20 °C
Operating temperature: -20 °C...60 °C
Storage temperature: -20 °C...85 °C
MTBF: 315 Years
REACH SVHC: Lead 7439-92-1
Input current: 4…20mA
Output signal in case of wire break: < 1 mA
Sensor supply: 3.8…26 V DC
Type: intrinsically safe circuit, active (as current source) or passive (as current sink)
Voltage drop not powered: < 6 V
Voltage drop powered: < 4.5 V
Load stability: ≤ 0.01 % of end value / 100 Ω
Type: active (as current source) or passive (as current sink)
Influence of load resistance: ≤ 0.01% of span / 100 Ω
2-wire supply: ≤ 26 V DC
Output signal limit: < 28 mA
Output current: 4...20 mA
Load impedance current: ≤ 600 Ω
Alarm function: Signal limit exceeded, Line interruption at the input, No supply voltage, Device error
Type: Relay, 1 NC (voltage-free)
Continuous current: ≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2)
Configuration: With FDT/DTM software
Voltage supply: 19.2…31.2 V DC
Type of connection: PUSH IN
Power consumption: ≤ 1.9 W
Accuracy: < 0.1% span
Temperature coefficient: < 0.01% of span/°C (TU)
Step response time: ≤ 5 ms
Protection degree: IP20
Humidity: 0...95 % (no condensation)
EMC standards: DIN EN 61326, NE 21
Insulation voltage: 2.6 kV (input / output)
Rated voltage: 300 V
Voltage U0: Current loop 28 V / externally 10 V
Current I0: Current loop 93 mA / externally 10 mA
Power P0: Current loop 0.65 W / externally 0.1 W
Marking: II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
Installation location: Device installed in safe area, zone 2
Demand mode: High
Description of the "safe state": analogue Output ≤ 3.6 mA or output ≥ 21 mA
Device type: A
Hardware fault tolerance (HFT): 0
Mean Time To Repair (MTTR): 24 h
Safe Failure Fraction (SFF): 85 %
Tproof: 5 Years
Total failure rate for dangerous detected failures (λDD): 127 FIT
Total failure rate for dangerous undetected failures (λDU): 48 FIT
Total failure rate for safe detected failures (λSD): 0 FIT
Total failure rate for safe undetected failures (λSU): 164 FIT
Safety category: SIL 2
Type of connection: PUSH IN
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 14
Wire cross-section, solid, min.: 0.2 mm²
Wire cross-section, solid, max.: 2.5 mm²
Wire connection cross-section, finely stranded, min.: 0.2 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 2.5 mm²
ETIM 6.0: EC002653
ETIM 7.0: EC002653
eClass 9.0: 27-21-01-20
eClass 9.1: 27-21-01-90
eClass 10.0: 27-21-01-20
ROHS: Conform
Type: ACT20X-2HAI-2SAO-P
Order No.: 2456150000
Version: EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, 2-channel
GTIN (EAN): 4050118471281
Qty.: 1 pc(s).
Width: 22.5 mm
Width (inches): 0.886 inch
Height: 127.3 mm
Height (inches): 5.012 inch
Depth: 114.6 mm
Depth (inches): 4.512 inch
Net weight: 212 g
Humidity: 0...95 % (no condensation)
Operating temperature, max.: 60 °C
Operating temperature, min.: -20 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -20 °C
Operating temperature: -20 °C...60 °C
Storage temperature: -20 °C...85 °C
MTBF: 315 Years
REACH SVHC: Lead 7439-92-1
Input current: 4…20mA
Output signal in case of wire break: < 1 mA
Sensor supply: 3.8…26 V DC
Type: intrinsically safe circuit, active (as current source) or passive (as current sink)
Voltage drop not powered: < 6 V
Voltage drop powered: < 4.5 V
Load stability: ≤ 0.01 % of end value / 100 Ω
Type: active (as current source) or passive (as current sink)
Influence of load resistance: ≤ 0.01% of span / 100 Ω
2-wire supply: ≤ 26 V DC
Output signal limit: < 28 mA
Output current: 4...20 mA
Load impedance current: ≤ 600 Ω
Alarm function: Signal limit exceeded, Line interruption at the input, No supply voltage, Device error
Type: Relay, 1 NC (voltage-free)
Continuous current: ≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2)
Configuration: With FDT/DTM software
Voltage supply: 19.2…31.2 V DC
Type of connection: PUSH IN
Power consumption: ≤ 1.9 W
Accuracy: < 0.1% span
Temperature coefficient: < 0.01% of span/°C (TU)
Step response time: ≤ 5 ms
Protection degree: IP20
Humidity: 0...95 % (no condensation)
EMC standards: DIN EN 61326, NE 21
Insulation voltage: 2.6 kV (input / output)
Rated voltage: 300 V
Voltage U0: Current loop 28 V / externally 10 V
Current I0: Current loop 93 mA / externally 10 mA
Power P0: Current loop 0.65 W / externally 0.1 W
Marking: II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
Installation location: Device installed in safe area, zone 2
Demand mode: High
Description of the "safe state": analogue Output ≤ 3.6 mA or output ≥ 21 mA
Device type: A
Hardware fault tolerance (HFT): 0
Mean Time To Repair (MTTR): 24 h
Safe Failure Fraction (SFF): 85 %
Tproof: 5 Years
Total failure rate for dangerous detected failures (λDD): 127 FIT
Total failure rate for dangerous undetected failures (λDU): 48 FIT
Total failure rate for safe detected failures (λSD): 0 FIT
Total failure rate for safe undetected failures (λSU): 164 FIT
Safety category: SIL 2
Type of connection: PUSH IN
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 14
Wire cross-section, solid, min.: 0.2 mm²
Wire cross-section, solid, max.: 2.5 mm²
Wire connection cross-section, finely stranded, min.: 0.2 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 2.5 mm²