2456070000
ACT20X-HDI-SDO-P
Type: | ACT20X-HDI-SDO-P |
Order No.: | 2456070000 |
Version: | EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: Optocoupler, 1-channel |
GTIN (EAN): | 4050118471267 |
Qty.: | 1 pc(s). |
Width: | 22.5 mm |
Width (inches): | 0.886 inch |
Height: | 127.3 mm |
Height (inches): | 5.012 inch |
Depth: | 114.6 mm |
Depth (inches): | 4.512 inch |
Net weight: | 170 g |
Humidity: | 0...95 % (no condensation) |
Operating temperature, max.: | 60 °C |
Operating temperature, min.: | -20 °C |
Storage temperature, max.: | 85 °C |
Storage temperature, min.: | -20 °C |
Operating temperature: | -20 °C...60 °C |
Storage temperature: | -20 °C...85 °C |
MTBF: | 215 Years |
REACH SVHC: | Lead 7439-92-1 |
Input frequency: | 0...5 kHz |
Input resistance: | 1 kΩ |
Output signal in case of wire break: | < 0.1 mA, > 6.5 mA (in case of wire break) |
Pulse duration: | > 0.1 ms |
Resistance: | Series resistor 750Ω, Parallel resistor 15kΩ |
Sensor: | NAMUR sensor, according to EN60947-5-6, switch with or without RS, RP |
Sensor supply: | 8 V DC / 8 mA |
Trigger level high: | > 2.1 mA |
Trigger level low: | < 1.2 mA |
Type: | intrinsically safe circuit |
Alarm function: | Line interruption at the input, Short circuit at input, No supply voltage, Device error |
Type: | Relay, 1 NC (voltage-free) |
Continuous current: | ≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2) |
Configuration: | With FDT/DTM software |
Voltage supply: | 19.2…31.2 V DC |
Type of connection: | PUSH IN |
NAMUR supply: | 8 V DC / 8 mA |
Power consumption: | ≤ 1.1 W |
Protection degree: | IP20 |
Humidity: | 0...95 % (no condensation) |
EMC standards: | DIN EN 61326, NE 21 |
Insulation voltage: | 2.6 kV (input / output) |
Rated voltage: | 300 V |
Type: | NPN-Transitor |
Nominal switching voltage: | 30 V DC |
Continuous current: | 80 mA |
Function: | Output = input, direct or inverse (configurable) |
Voltage U0: | 10.6 V DC |
Current I0: | 12 mA DC |
Power P0: | 32 mW |
Marking: | II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I |
Installation location: | Device installed in safe area, zone 2 |
Demand mode: | High |
Demand rate: | 1,000 s |
Description of the "safe state": | High impedance |
Device type: | B |
Diagnostic test interval: | 10 s |
Hardware fault tolerance (HFT): | 0 |
Mean Time To Repair (MTTR): | 8 h |
Safe Failure Fraction (SFF): | 92 % |
Tproof: | 5 Years |
Total failure rate for dangerous detected failures (λDD): | 135 FIT |
Total failure rate for dangerous undetected failures (λDU): | 36 FIT |
Total failure rate for safe detected failures (λSD): | 0 FIT |
Total failure rate for safe undetected failures (λSU): | 275 FIT |
Safety category: | SIL 2 |
Type of connection: | PUSH IN |
Wire connection cross section AWG, min.: | AWG 26 |
Wire connection cross section AWG, max.: | AWG 14 |
Wire cross-section, solid, min.: | 0.2 mm² |
Wire cross-section, solid, max.: | 2.5 mm² |
Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
Wire connection cross section, finely stranded, max.: | 2.5 mm² |
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
ETIM 6.0: | EC002653 |
ETIM 7.0: | EC002653 |
eClass 9.0: | 27-21-01-20 |
eClass 9.1: | 27-21-01-20 |
eClass 10.0: | 27-21-01-20 |
ROHS: | Conform |
Type: | ACT20X-HDI-SDO-P |
Order No.: | 2456070000 |
Version: | EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: Optocoupler, 1-channel |
GTIN (EAN): | 4050118471267 |
Qty.: | 1 pc(s). |
Width: | 22.5 mm |
Width (inches): | 0.886 inch |
Height: | 127.3 mm |
Height (inches): | 5.012 inch |
Depth: | 114.6 mm |
Depth (inches): | 4.512 inch |
Net weight: | 170 g |
Humidity: | 0...95 % (no condensation) |
Operating temperature, max.: | 60 °C |
Operating temperature, min.: | -20 °C |
Storage temperature, max.: | 85 °C |
Storage temperature, min.: | -20 °C |
Operating temperature: | -20 °C...60 °C |
Storage temperature: | -20 °C...85 °C |
MTBF: | 215 Years |
REACH SVHC: | Lead 7439-92-1 |
Input frequency: | 0...5 kHz |
Input resistance: | 1 kΩ |
Output signal in case of wire break: | < 0.1 mA, > 6.5 mA (in case of wire break) |
Pulse duration: | > 0.1 ms |
Resistance: | Series resistor 750Ω, Parallel resistor 15kΩ |
Sensor: | NAMUR sensor, according to EN60947-5-6, switch with or without RS, RP |
Sensor supply: | 8 V DC / 8 mA |
Trigger level high: | > 2.1 mA |
Trigger level low: | < 1.2 mA |
Type: | intrinsically safe circuit |
Alarm function: | Line interruption at the input, Short circuit at input, No supply voltage, Device error |
Type: | Relay, 1 NC (voltage-free) |
Continuous current: | ≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2) |
Configuration: | With FDT/DTM software |
Voltage supply: | 19.2…31.2 V DC |
Type of connection: | PUSH IN |
NAMUR supply: | 8 V DC / 8 mA |
Power consumption: | ≤ 1.1 W |
Protection degree: | IP20 |
Humidity: | 0...95 % (no condensation) |
EMC standards: | DIN EN 61326, NE 21 |
Insulation voltage: | 2.6 kV (input / output) |
Rated voltage: | 300 V |
Type: | NPN-Transitor |
Nominal switching voltage: | 30 V DC |
Continuous current: | 80 mA |
Function: | Output = input, direct or inverse (configurable) |
Voltage U0: | 10.6 V DC |
Current I0: | 12 mA DC |
Power P0: | 32 mW |
Marking: | II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I |
Installation location: | Device installed in safe area, zone 2 |
Demand mode: | High |
Demand rate: | 1,000 s |
Description of the "safe state": | High impedance |
Device type: | B |
Diagnostic test interval: | 10 s |
Hardware fault tolerance (HFT): | 0 |
Mean Time To Repair (MTTR): | 8 h |
Safe Failure Fraction (SFF): | 92 % |
Tproof: | 5 Years |
Total failure rate for dangerous detected failures (λDD): | 135 FIT |
Total failure rate for dangerous undetected failures (λDU): | 36 FIT |
Total failure rate for safe detected failures (λSD): | 0 FIT |
Total failure rate for safe undetected failures (λSU): | 275 FIT |
Safety category: | SIL 2 |
Type of connection: | PUSH IN |
Wire connection cross section AWG, min.: | AWG 26 |
Wire connection cross section AWG, max.: | AWG 14 |
Wire cross-section, solid, min.: | 0.2 mm² |
Wire cross-section, solid, max.: | 2.5 mm² |
Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
Wire connection cross section, finely stranded, max.: | 2.5 mm² |
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
ETIM 6.0: | EC002653 |
ETIM 7.0: | EC002653 |
eClass 9.0: | 27-21-01-20 |
eClass 9.1: | 27-21-01-20 |
eClass 10.0: | 27-21-01-20 |
ROHS: | Conform |
ECCN: | |
Country of Origin: | |
EAN: | |
Weight: | 0.18 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |