103016677
BWU3565
Suitable for AZM 400. Protection class IP67. Safe active AS-i distributor. M12, 8-pole connecting cable 1 m. Connections for profile cable AS-i & AUX. With 2 fail-safe inputs for OSSDs and one digital, output that is not fail-safe
Product type description: | BWU3565 |
Article number (order number): | 103016677 |
EAN (European Article Number): | 4030661508917 |
Product name: | BWU3565 |
Standards: | ISO 13849-1 EN 62061 EN 62026-2 |
Enclosure material: | Plastic |
Weight: | 100 g |
Reaction time, maximum: | 11 ms |
Safety functions: | Yes |
Integral System Diagnostics, status: | Yes |
Standards: | EN 62061 |
Performance Level: | e |
Control category to EN13849: | 4 |
PFH-value: | 5.18 x 10-9 /h |
PFD value: | 6.19 x 10⁻⁷ |
Safety Integrity Level (SIL): | 3 |
Mission Time: | 20 Year(s) |
Terminal Connector: | Cable connector M12, 8-pole, A-coded |
Length of cable: | 1 m |
Material of the cable: | PUR |
Width: | 60 mm |
Height: | 45 mm |
Depth: | 19 mm |
Protection class: | IP67 |
Ambient temperature, minimum: | -20 °C |
Ambient temperature, maximum: | +60 °C |
Storage and transport temperature, minimum: | -30 °C |
Storage and transport temperature, maximum: | +85 °C |
Resistance to vibrations to EN 60068-2-6: | 10 … 55 Hz, amplitude 0.5 mm |
Restistance to shock: | 15 g / 11 ms |
AS-i Operating voltage, minimum: | 21.6 VDC |
AS-i Operating voltage AS-i maximum: | 31.6 VDC |
AS-i Current consumption, maximum: | 60 mA |
AS-i Specification: | Safety-Slave |
AS-i Version: | V 2.1 |
AS-i Profile: | S-7.B.F.1 |
AS-i Input, Channel 1: | Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2: | Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0: | Digital output, Motor control system |
AS-i Outputs, DO 1 … DO 3: | No Function |
AS-i Parameter bits, P0: | Control system watchdog |
AS-i Parameter bits, P1: | Diagnostics signal safety switchgear (inverted) |
AS-i Parameter bits, P2 ... P3: | No function |
Note (AS-i Parameter bits): | Set the parameter outputs to "1111" (0xF) |
AS-i Input module address: | 0 |
Note (AS-i Input module address): | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Note (LED switching conditions display): | (1) green/red LED (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected (2) LED green: AUX-Power available (3) LED yellow: S1 = Status safety input 1 (4) LED yellow: S2 = Status safety input 2 (5) LED yellow: I1 = Status input I1 (6) LED yellow: o1 = Status output o1 |
Hinweis (LED-Zustandsanzeige): | (1) grün/rote LED (AS-i Duo LED): Versorgungsspannung / Kommunikationsfehler / Slaveadresse = 0 / Peripheriefehler erkannt (2) grüne LED: AUX-Power vorhanden (3) gelbe LED : S1 = Status Sicherheitseingang 1 (4) gelbe LED: S2 = Status Sicherheitseingang 2 (5) gelbe LED : I1 = Status Eingang I1 (6) gelbe LED : o1 = Status Ausgang o1 |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.14 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |