101213904
CSS 11-300-D-M-ST
Ø M30. Connector M12, 8-pole. Thermoplastic enclosure. Max. length of the sensor chain 200 m. Max. 31 sensors can be wired in series. 2 short-circuit proof PNP safety outputs. High repeat accuracy of the switching points. Safety sensor can also be installed behind V4A, covers. Integral cross-short, wire-breakage and external, voltage monitoring of the safety cables up to the, control cabinet
| Product type description: | CSS 11-300-D-M-ST |
| Article number (order number): | 101213904 |
| EAN (European Article Number): | 4030661405650 |
| eCl@ss number, Version 9.0: | 27-27-24-03 |
| Certificates: | cULus EAC |
| Product name: | CSS 300 |
| Standards: | IEC 60947-5-3 ISO 13849-1 |
| Active principle: | inductive |
| Housing construction form: | Cylinder, thread |
| Installation conditions (mechanical): | not flush |
| Sensor topology: | Sensor for series wiring |
| Enclosure material: | Plastic |
| Active area: | Plastic |
| Weight: | 245 g |
| Reaction time, maximum: | 60 ms |
| Duration of risk, maximum: | 60 ms |
| Diagnostic output: | Yes |
| Short circuit detection: | Yes |
| Short-circuit recognition: | Yes |
| Safety functions: | Yes |
| Cascadable: | Yes |
| Integral System Diagnostics, status: | Yes |
| Number of LEDs: | 2 |
| Number of semi-conductor outputs with signaling function: | 1 |
| Number of fail-safe digital outputs: | 2 |
| Number of Series-wiring of sensors: | 31 |
| Standards: | IEC 60947-5-3 IEC 61508 |
| Performance Level: | e |
| Control category to EN13849: | 4 |
| PFH-value: | 3.60 x 10-9 /h |
| Safety Integrity Level (SIL): | 3 |
| Mission Time: | 20 Year(s) |
| Actuating panels: | Actuation from top |
| Active area: | front side |
| Switch distance: | 11 mm |
| Ensured switch distance "ON" Sao: | 8 mm |
| Ensured switch distance "OFF" Sar: | 15 mm |
| Hysteresis (Switch distance), maximum: | 2 mm |
| Repeat accuracy R R: | 1 mm |
| Note: | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current |
| ISO thread of the sensor: | M30 |
| Length of sensor: | 99.5 mm |
| Protection class: | IP69 to IEC 60529 |
| Ambient temperature, minimum: | -25 °C |
| Ambient temperature, maximum: | +65 °C |
| Storage and transport temperature, minimum: | -25 °C |
| Storage and transport temperature, maximum: | +85 °C |
| Resistance to vibrations to EN 60068-2-6: | 10 … 55 Hz, amplitude 1 mm |
| Restistance to shock: | 30 g / 11 ms |
| Rated impulse withstand voltage: | 0.8 kV |
| Degree of pollution to VDE 0100: | 3 |
| Voltage type: | DC (direct current) |
| No-load current: | 100 mA |
| Rated operating voltage, minimum: | 20.4 VDC |
| Rated operating voltage, maximum: | 26.4 VDC |
| Operating current: | 600 mA |
| Required rated short-circuit current to EN 60947-5-1: | 100 A |
| Switching frequency, approx.: | 3 Hz |
| Rated operating current (safety outputs): | 250 mA |
| Output current, (fail-safe output), maximum: | 0.25 A |
| Current leakage: | 0.5 mA |
| PIN 1: | 1A1 Ue: (1) |
| PIN 2: | X1 Safety input 1 |
| PIN 3: | A2 GND |
| PIN 4: | Y1 Safety output 1 |
| PIN 5: | OUT Diagnostic output |
| PIN 6: | X2 Safety input 2 |
| PIN 7: | Y2 Safety output 2 |
| PIN 8: | IN without function |
| Included in delivery: | Actuators must be ordered separately. |
| Delivery scope of Mounting material: | 2x Mounting accessories Nuts M30 |
| Recommendation (actuator): | CST 30S-1 |
| Note (General): | Evaluation requirements: The switch-off pauses of 250 µs – 1500 µs must be tolerated by the evaluation. The switch-off time of the safety sensor of 250 μs is additionally extended according the cable length and the capacity of the cable used. Typically a switch off time of 500 μs with 100 m of connection cable is reached. |
| Spannung, Gebrauchskategorie DC13: | 24 VDC |
| Strom, Gebrauchskategorie DC13: | 0,05 A |
| Störaussendung: | IEC 61000-6-4 |
| Störfestigkeit: | IEC 61000-6-2 |
| PIN 1: | A1 Ue |
| PIN 2: | X1 Sicherheitseingang 1 |
| PIN 3: | A2 GND |
| PIN 4: | Y1 Sicherheitsausgang 1 |
| PIN 5: | OUT Diagnoseausgang |
| PIN 6: | X2 Sicherheitseingang 2 |
| PIN 7: | Y2 Sicherheitsausgang 2 |
| PIN 8: | IN ohne Funktion |
| Lieferumfang: | Die Betätiger sind nicht im Lieferumfang enthalten. |
| Lieferumfang des Montagematerials: | 2x Befestigungsmaterial Muttern M30 |
| Empfehlung (Betätiger): | CST 30S-1 |
| Empfehlung Sicherheitsschaltgerät: | PROTECT PSC1 SRB-E-301ST SRB-E-201LC |
| Hinweis (Allgemein): | Anforderungen an die Auswertung: Die Abschaltpausen von 250 µs –1500 µs müssen von der Auswertung toleriert werden. Die Abschaltzeit des Sicherheits-Sensors von 250 µs verlängert sich zusätzlich in Abhängigkeit von der Leitungslänge und der Kapazität der eingesetzten Leitung. Typisch wird eine Abschaltpause von 500 µs mit 100 m Anschlussleitung erreicht. |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.14 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |