101190593
SRB301HC/T-24V
1 Signalling output. 3 safety contacts, STOP 0. Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks and Safety mats
Product type description: | SRB301HC/T-24V |
Article number (order number): | 101190593 |
EAN (European Article Number): | 4250116202331 |
eCl@ss number, Version 9.0: | 27-37-18-19 |
Replacement article number: | 101193478 |
Certificates: | TÜV cULus CCC EAC TILVA |
Product name: | SRB301HC/T |
Standards: | IEC 61508 IEC/EN 60204-1 ISO 13849-1 EN 60947-5-1 |
Climatic stress: | EN 60068-2-78 |
Enclosure material: | Glass-fibre reinforced thermoplastic, ventilated |
Material of the contacts, electrical: | AgSn0. self-cleaning, positive drive |
Weight: | 380 g |
Stop-Category: | 0 |
Electronic Fuse: | Yes |
Wire breakage detection: | Yes |
Short-circuit recognition: | Yes |
Removable Terminals: | Yes |
Start input: | Yes |
Feedback circuit: | Yes |
Automatic reset function: | Yes |
Earth connection detection: | Yes |
Integral System Diagnostics, status: | Yes |
Number of auxiliary contacts: | 1 |
Number of LEDs: | 4 |
Number of openers: | 2 |
Number of safety contacts: | 3 |
Standards: | EN 60947-5-1 IEC 61508 |
Performance Level, Stop 0: | e |
Category, Stop 0: | 4 |
Diagnostic Coverage (DC) Level, Stop 0: | ≥ 99 % |
PFH-Value Stop 0: | 2.00 x 10⁻⁸ /h |
Safety Integrity Level (SIL), Stop 0: | 3 |
Mounting: | Snaps onto standard DIN rail to EN 60715 |
Mechanical life, minimum: | 10,000,000 Operations |
Terminal Connector: | Screw connection rigid or flexible |
Terminal designations: | IEC/EN 60947-1 |
Cable section, minimum: | 0.25 mm² |
Cable section, maximum: | 2.5 mm² |
Tightening torque of Clips: | 0.6 Nm |
Width: | 45 mm |
Height: | 100 mm |
Depth: | 121 mm |
Protection class of the enclosure: | IP40 |
Protection class of the Clearance: | IP54 |
Protection class of Clips or Terminals: | IP20 |
Ambient temperature, minimum: | -25 °C |
Ambient temperature, maximum: | +60 °C |
Storage and transport temperature, minimum: | -40 °C |
Storage and transport temperature, maximum: | +85 °C |
Resistance to vibrations to EN 60068-2-6: | 10 ... 55 Hz, Amplitude 0.35 mm |
Restistance to shock: | 30 g / 11 ms |
Rated impulse withstand voltage: | 4 kV |
Degree of pollution to IEC/EN 60664-1: | 2 |
Frequency range: | 50 Hz 60 Hz |
Rated operating voltage: | 24 VAC -15% / +10% 24 VDC -15%/+20%, residual ripple max. 10% |
Rated AC voltage for controls, 50 Hz, minimum: | 20.4 VAC |
Rated control voltage at AC 50 Hz, maximum: | 26.4 VAC |
Rated AC voltage for controls, 60 Hz, minimum: | 20.4 VAC |
Rated control voltage at AC 60 Hz, maximum: | 26.4 VAC |
Rated AC voltage for controls at DC minimum: | 20.4 VDC |
Rated control voltage at DC, maximum: | 28.8 VDC |
Electrical power consumption: | 1.6 W |
Electrical power consumption: | 3.7 VA |
Contact resistance, maximum: | 0.1 Ω |
Note (Contact resistance): | in new state |
Drop-out delay in case of power failure, typically: | 80 ms |
Drop-out delay in case of emergency, typically: | 20 ms |
Pull-in delay at automatic start, maximum, typically: | 100 ms |
Pull-in delay at RESET, typically: | 20 ms |
Switching capacity, minimum: | 10 VDC |
Switching capacity, minimum: | 10 mA |
Switching capacity, maximum: | 250 VAC |
Switching capacity, maximum: | 8 A |
Conduction resistance, maximum: | 40 Ω |
Switching capacity, maximum: | 24 VDC |
Switching capacity, maximum: | 2 A |
Indicated operating states: | Position relay K2 Position relay K1 |
Note (applications): | Guard system Emergency-Stop button Pull-wire emergency stop switches Safety mats |
Note (General): | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
Note (Wiring diagram): | The wiring diagram is shown with guard doors closed and in de-energised condition. Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. The control recognises cross-short, cable break and earth leakages in the monitoring circuit. 2 channel control shown for a guard-door monitor with two contacts, of which at least one contact has positive break, with external reset button (R). (H2) = Feedback circuit |
Leitungswiderstand, maximum: | 40 Ω |
Spannung, Gebrauchskategorie DC12: | 24 VDC |
Strom, Gebrauchskategorie DC12: | 0,1 A |
Schaltvermögen, maximum: | 24 VDC |
Schaltvermögen, maximum: | 2 A |
Störfestigkeit: | EMV-Richtlinie |
Angezeigte Funktionszustände: | Stellung der Relais K2 Stellung der Relais K1 |
Hinweis (Applikationsanwendungen): | Schutzeinrichtung NOT-HALT-Taster Seilzug-Notschalter Sicherheits-Schaltmatte |
Hinweis (Allgemein): | Induktive Verbraucher (Schütze, Relais etc.) sind durch eine geeignete Beschaltung zu entstören. |
Hinweis (Schaltungsbeispiel): | Das Schaltungsbeispiel ist bei geschlossenen Schutzeinrichtungen und im spannungslosen Zustand dargestellt. Leistungsebene: 2-kanalige Ansteuerung geeignet zur Kontaktverstärkung bzw. Kontaktvervielfältigung durch Schütze oder Relais mit zwangsgeführten Kontakten. Die Ansteuerung erkennt Querschlüsse, Drahtbrüche und Erdschlüsse im Überwachungskreis. 2-kanalige Ansteuerung dargestellt am Beispiel einer Schutztürüberwachung mit zwei Kontakten, davon mindestens ein Kontakt zwangsöffnend; mit externem Reset-Taster (R). (H2) = Rückführkreis |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.29 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |