Article image 101172152

Schmersal 101172152

AZM 161SK-12/12RKN-024

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Long life. 6 Contacts. Double-insulated. Emergency release. 130 mm x 90 mm x 30 mm. Thermoplastic enclosure. Large wiring compartment, cable entries 4 M 16 x 1.5. Interlock with protection against incorrect, locking.

Technical parameters

Product type description: AZM 161SK-12/12RKN-024
Article number (order number): 101172152
EAN (European Article Number): 4030661306865
eCl@ss number, Version 9.0: 27-27-26-03
Certificates: CE cULus CCC EAC
Product name: AZM 161
Standards: EN 60947-5-1 BG-GS-ET-19
Active principle: electromechanical
Enclosure material: Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Material of the contacts, electrical: Silver
Weight: 435 g
Power to unlock: Yes
Emergency release: Yes
Number of actuating directions: 3
Number of auxiliary contacts: 2
Number of safety contacts: 4
Standards: ISO 13849-1
Mission Time: 20 Year(s)
B10d Normally-closed contact (NC): 2,000,000 Operations
B10d Normally open contact (NO): 1,000,000 Operations
Mechanical life, minimum: 1,000,000 Operations
Actuating play in direction of actuation: 5.5 mm
Clamping force: 2,000 N
Latching force: 30 N
positive break travel: 9.5 mm
Positive break force, minimum: 20 N
Actuating speed, maximum: 2 m/s
Terminal Connector: Screw terminals
Cable section, minimum: 1 x 0.25 mm²
Cable section, maximum: 1 x 1.5 mm²
Note (Cable section): All indications about the cable section are including the conductor ferrules.
Height of sensor: 90 mm
Length of sensor: 30 mm
Width of sensor: 130 mm
Protection class: IP 67 to IEC/EN 60529
Ambient temperature, minimum: -25 °C
Ambient temperature, maximum: +60 °C
Rated impulse withstand voltage: 4 kV
Thermal test current: 6 A
Required rated short-circuit current to EN 60947-5-1: 1,000 A
Electrical power consumption, maximum: 10 W
Switching element: NO contact, NC contact
Switching principle: Creep circuit element
Switching frequency: 1,000 /h
Note (applications): sliding safety guard removable guard hinged safety guard
Included in delivery: Actuators must be ordered separately.
Note (Emergency release): For cases of danger Mounting only outside the guarded area
Strom, Gebrauchskategorie AC15: 4 A
Spannung, Gebrauchskategorie DC13: 24 VDC
Strom, Gebrauchskategorie DC13: 2,5 A
Spannung, Gebrauchskategorie AC15: 230 VAC
Strom, Gebrauchskategorie AC15: 4 A
Spannung, Gebrauchskategorie DC13: 24 VDC
Strom, Gebrauchskategorie DC13: 2,5 A
Hinweis (Applikationsanwendungen): verschiebbare Schutzeinrichtung abnehmbare Schutzeinrichtung drehbare Schutzeinrichtung
Lieferumfang: Die Betätiger sind nicht im Lieferumfang enthalten.
Hinweis (Fluchtentriegelung): Im Notfall Anbau nur außerhalb der Schutzeinrichtung

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.44 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m