101165883
SE-304 C AUSWERTEGERAET
1 Signalling output. 1 safety contact, STOP 0. To monitor 1 .. 4 safety edge(s)
Product type description: | SE-304C |
Article number (order number): | 101165883 |
EAN (European Article Number): | 4030661293622 |
eCl@ss number, Version 9.0: | 27-37-18-19 |
Certificates: | TÜV EAC |
Product name: | SE-304C |
Standards: | ISO 13849-1 EN ISO 13850 |
Climatic stress: | EN ISO 13856-2 |
Enclosure material: | Glass-fibre, thermoplastic |
Weight: | 175 g |
Reaction time, maximum: | 17 ms |
Stop-Category: | 0 |
Electronic Fuse: | Yes |
Wire breakage detection: | Yes |
Short-circuit recognition: | Yes |
Start input: | Yes |
Feedback circuit: | Yes |
Automatic reset function: | Yes |
Reset edge detection: | Yes |
Reset after disconnection of supply voltage: | Yes |
Earth connection detection: | Yes |
Integral System Diagnostics, status: | Yes |
Number of LEDs: | 5 |
Number of undelayed semi-conductor outputs with signaling function: | 1 |
Number of safety contacts: | 1 |
Number of signalling outputs: | 1 |
Performance Level: | d |
Control category to EN13849: | 3 |
Control category to EN954: | 3 |
PFH-value: | 1.01 x 10⁻⁷ /h |
Note (PFH-value): | up to max. 5,000 switching cycles/year |
Mission Time: | 20 Year(s) |
Mounting: | Snaps onto standard DIN rail to EN 60715 |
Mechanical life, minimum: | 10,000,000 Operations |
Terminal Connector: | Screw connection |
Length of cable: | 200 m |
Cable section, maximum: | 2 x 1.5 mm² |
Note (Cable section): | All indications about the cable section are including the conductor ferrules. |
Width: | 22.5 mm |
Height: | 100 mm |
Depth: | 121 mm |
Protection class of the enclosure: | IP40 |
Protection class of the Clearance: | IP54 |
Protection class of Clips or Terminals: | IP20 |
Ambient temperature, minimum: | +5 °C |
Ambient temperature, maximum: | +55 °C |
Resistance to vibrations to EN 60068-2-6: | 10 … 55 Hz, amplitude 0.15 mm |
Rated impulse withstand voltage: | 4 kV |
Degree of pollution to VDE 0110: | 2 |
Frequency range: | 50 Hz |
Rated operating voltage: | 24 VDC +20% / -10% 24 VAC +10% / -10% |
Operating current: | 500 mA |
Rated AC voltage for controls, 50 Hz, minimum: | 21.6 VAC |
Rated control voltage at AC 50 Hz, maximum: | 28.8 VAC |
Rated AC voltage for controls at DC minimum: | 21.6 VDC |
Rated control voltage at DC, maximum: | 28.8 VDC |
Utilisation category AC-15: | 230 VAC |
Utilisation category AC-15: | 2 A |
Utilisation category DC-13: | 24 VDC |
Utilisation category DC-13: | 2 A |
Electrical power consumption, maximum: | 4 W |
Pull-in delay at RESET: | 100 ms ... 2000 ms |
Indicated operating states: | Authorised operation fault indication |
Note (applications): | Safety edges |
Note (General): | The overall machine safety depends on the professional mounting and installation of the safety monitoring module and the signal transmitter, as well as on the correct and professional electrical connection of the components. If there it any risk whatsoever, the machine may not be restarted. |
Note (Wiring diagram): | Both re-initialisation and auto-reset must comply with the requirements of EN 1760-2 (diagram A2, A3). The wiring diagram is shown for the de-energised condition. Monitoring the safety edges SE 40 / SE 70 with a safety monitoring unit SE-304C up to PL d and Category 3. Manual reset function or auto-reset: the manual reset function is triggered by an edge-sensitive signal (edge switching "0-1-0" within 100 ms up to 2 s) (X2/X3). Alternatively, the auto-reset function can be activated by a connection (A3/X2). If less than 4 safety edges are connected, the following diagram must be observed. |
Hinweis (Allgemein): | Die Gesamtsicherheit der Maschine ist von der fachgerechten Montage und Installation von Sicherheitsbaustein und Signalgeber, sowie von der fachgerechten elektrischen Verbindung der Baugruppen abhängig. Bei bestehender Gefahr darf die Maschine nicht erneut gestartet werden. |
Hinweis (Schaltungsbeispiel): | Manueller Reset und Autoreset muss den Anforderungen der EN 1760-2 (Zustandsdiagramm A2, A3) entsprechen. Das Schaltungsbeispiel ist im spannungslosen Zustand dargestellt. Überwachung der Sicherheits-Schaltleisten SE 40 / SE 70 mit einem Sicherheitsbaustein SE-304C bis zu PL d und Kategorie 3. Wahlweise Rückstellfunktion oder Autoreset: Die Rückstellfunktion wird durch ein flankensensitives Signal (Flankenwechsel "0-1-0" innerhalb von 100 ms bis 2 s) ausgelöst (X2/X3). Alternativ kann die Autoresetfunktion durch durch eine Verbindung (A3/X2) aktiviert werden. Werden weniger als 4 Schaltleisten angeschlossen, ist nach dem folgenden Schema anzuschließen. |
ECCN: | |
Country of Origin: | CZ |
EAN: | |
Weight: | 0.18 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |