Article image 101153920

Schmersal 101153920

SE-400 C AUSWERTEGERAET

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

1 Signalling output. 2 safety contacts, STOP 0. To monitor 1 safety edge(s)

Technical parameters

Product type description: SE-400C
Article number (order number): 101153920
EAN (European Article Number): 4030661289175
eCl@ss number, Version 9.0: 27-37-18-19
Certificates: TÜV cULus EAC
Product name: SE-400C
Standards: ISO 13849-1 EN ISO 13850
Climatic stress: EN ISO 13856-2
Enclosure material: Plastic, PE (Black), Crastin (Grey)
Weight: 184 g
Time to readiness, maximum: 32 ms
Reaction time, maximum: 32 ms
Stop-Category: 0
Electronic Fuse: Yes
Wire breakage detection: Yes
Short-circuit recognition: Yes
Start input: Yes
Feedback circuit: Yes
Automatic reset function: Yes
Reset edge detection: Yes
Reset after disconnection of supply voltage: Yes
Earth connection detection: Yes
Integral System Diagnostics, status: Yes
Number of LEDs: 2
Number of undelayed semi-conductor outputs with signaling function: 1
Number of safety contacts: 2
Number of signalling outputs: 1
Performance Level: e
Control category to EN13849: 4
Control category to EN954: 4
PFH-value: 2.47 x 10⁻⁸ /h
Note (PFH-value): up to max. 50,000 switching cycles/year
Mission Time: 20 Year(s)
Mounting: Snaps onto standard DIN rail to EN 60715
Mechanical life, minimum: 30,000,000 Operations
Terminal Connector: Screw connection
Length of cable: 200 m
Cable section, maximum: 2 x 1.5 mm²
Note (Cable section): All indications about the cable section are including the conductor ferrules.
Width: 22.5 mm
Height: 100 mm
Depth: 121 mm
Protection class of the enclosure: IP40
Protection class of the Clearance: IP54
Protection class of Clips or Terminals: IP20
Ambient temperature, minimum: +5 °C
Ambient temperature, maximum: +55 °C
Resistance to vibrations to EN 60068-2-6: 10 … 55 Hz, amplitude 0.15 mm
Rated impulse withstand voltage: 4 kV
Degree of pollution to VDE 0110: 2
Rated operating voltage: 24 VDC +20% / -10%
Operating current: 150 mA
Rated AC voltage for controls at DC minimum: 21.6 VDC
Rated control voltage at DC, maximum: 28.8 VDC
Utilisation category AC-15: 230 VAC
Utilisation category AC-15: 2 A
Utilisation category DC-13: 24 VDC
Utilisation category DC-13: 3 A
Electrical power consumption, maximum: 4 W
Indicated operating states: Safety edge function
Note (applications): Safety edges
Note (General): The overall machine safety depends on the professional mounting and installation of the safety monitoring module and the signal transmitter, as well as on the correct and professional electrical connection of the components. If there it any risk whatsoever, the machine may not be restarted.
Note (Wiring diagram): A Start-Reset-Taster (S) can optionally be connected to the feedback circuit. Both re-initialisation and auto-reset must comply with the requirements of EN 1760-2 (diagram A2, A3). The wiring diagram is shown for the de-energised condition. Monitoring the safety edges SE 40 / SE 70 with a safety monitoring unit SE-400C up to PL e and Category 4. The feedback circuit monitors the position of the contactors KA and KB.
Hinweis (Allgemein): Die Gesamtsicherheit der Maschine ist von der fachgerechten Montage und Installation von Sicherheitsbaustein und Signalgeber, sowie von der fachgerechten elektrischen Verbindung der Baugruppen abhängig. Bei bestehender Gefahr darf die Maschine nicht erneut gestartet werden.
Hinweis (Schaltungsbeispiel): Ein Start-Reset-Taster (S) kann optional in den Rückführkreis eingebunden werden. Manueller Reset und Autoreset muss den Anforderungen der EN 1760-2 (Zustandsdiagramm A2, A3) entsprechen. Das Schaltungsbeispiel ist im spannungslosen Zustand dargestellt. Überwachung der Sicherheits-Schaltleisten SE 40 / SE 70 mit einem Sicherheitsbaustein SE-400C bis zu PL e und Kategorie 4. Der Rückführkreis überwacht die Stellung der Schütze KA und KB.

Logistic parameters

ECCN:
Country of Origin: CZ
EAN:
Weight: 0.18 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m