KA0204
KAS-40-G1/2"-N-K-PEEK-Y7-100°C ATEX
Capacitive Sensors ATEX. Serie 40 – NAMUR EN 60947-5-6. Housing Ø 32 mm / G 1/2” / Ø 12 mm. For use in areas with the risk of explosion, zone 0. Housing material: PEEK. Sensing distance 1…4 mm adjustable. DMT 03 ATEX E 048 IECEx BVS 07.0031. II 1G Ex ia IIC T1-T6 Ga Ex ia IIC T1-T6 Ga
| Thread / Process connection: | G 1/2" |
| Housing material active surface: | PEEK (FDA 21 CFR 177.2415) |
| Housing material: | PEEK (FDA 21 CFR 177.2415) |
| Housing material lid: | PA / PPO |
| Electrical version: | 2-Polig DC |
| Permitted residual ripple max.: | 5% |
| Frequency of operating cycles max.: | 500 Hz |
| LEDdisplay: | Gelb |
| Protective circuit: | Eingebaut |
| Degree of protection IEC 60529: | IP 67 (mit versiegelter Potentiometerschraube) |
| Norm: | EN 60947-5-6 |
| Selfinductance (L): | 0,2 mH |
| Selfcapacitance (C): | 250 nF |
| Operating current active surface free: | < typ. 1,5 mA |
| Operating current active surface covered: | > typ. 2,5 mA |
| Sensing dinstance Sn: | 2 mm |
| Operating distance min. / max. adjustable: | 1…4 mm |
| Operating voltage: | 5…15 V DC, Ui = 15 V DC |
| Permitted ambient temperature min.: | -20 °C |
| Permitted ambient temperature max.: | +100 °C |
| Installation: | Nichtbündig |
| Output function: | NAMUR |
| Connection: | Steckerflansch M 8 x 1 |
| CE: | JA |
| RoHS: | JA |
| UL CSA certification: | JA |
| ATEX product marking gas: | Ex II 1G Ex ia Ex IIC T1 – T6 Ga |
| Certified Zones ATEX: | 1G |
| IECEX product marking gas: | Ex ia IIC T1 – T6 Ga |
| MTTF: | 1941,52 Jahre |
| WHG certification: | Auf Anfrage |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.00 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |