Width: 110 mm
Height: 130 mm
Depth: 160 mm
Installation distance right/left: 0 mm / 0 mm
Installation distance top/bottom: 50 mm / 50 mm
Degree of protection: IP20
Inflammability class in acc. with UL 94 (housing / terminal blocks): V0
Ambient temperature (operation): -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested): -40 °C
Ambient temperature (storage/transport): -40 °C ... 85 °C
Max. permissible relative humidity (operation): ≤ 95 % (at 25 °C, non-condensing)
Climatic class: 3K3 (in acc. with EN 60721)
Degree of pollution: 2
Installation height: ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
Nominal input voltage range: 3x 400 V AC ... 500 V AC
Input voltage range: 3x 400 V AC ... 500 V AC -20 % ....+15 %
AC frequency range: 50 Hz ... 60 Hz
Frequency range (fN): 50 Hz ... 60 Hz ±5 Hz
Discharge current to PE: < 3.5 mA
Current consumption: 3x 1.9 A (400 V AC)
Nominal power consumption: 1335.1 VA
Mains buffering time: > 10 ms (400 V AC)
Input fuse: 6.3 A (internal (device protection))
Recommended breaker for input protection: 10 A ... 16 A (Characteristics B, C, D, K)
Power factor (cos phi): 0.77
Type of protection: Transient surge protection
Protective circuit/component: Varistor
Nominal output voltage: 24 V DC ±1 %
Setting range of the output voltage (USet): 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN): 40 A
Dynamic Boost (IDyn.Boost): 60 A (5 s)
Derating: > 60 °C ... 70 °C (2.5%/K)
Connection in parallel: Yes, for redundancy and increased capacity
Connection in series: yes
Feedback voltage resistance: < 35 V
Protection against overvoltage at the output (OVP): ≤ 30 V DC
Control deviation: < 1 % (change in load, static 10 % ... 90 %)
Residual ripple: ≤ 50 mVPP
Output power: 960 W
Typical response time: < 1 s
Maximum power dissipation in no-load condition: typ. 14 W (400 V AC)
Power loss nominal load max.: < 70 W (480 V AC)
Short-circuit current: < 48 A DC (Permanent)
Net weight: 2.6 kg
Efficiency: typ. 93 % (400 V AC)
MTBF (IEC 61709, SN 29500): > 1730000 h (25 °C)
Insulation voltage input/output: 3 kV AC (type test)
Degree of protection: IP20
Protection class: I (in closed control cabinet)
Inflammability class in acc. with UL 94 (housing / terminal blocks): V0
Mounting position: horizontal DIN rail NS 35, EN 60715
Assembly instructions: alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
Connection method: Push-in connection
Conductor cross section solid min.: 0.2 mm²
Conductor cross section solid max.: 4 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Stripping length: 10 mm
Connection method: Push-in connection
Conductor cross section solid min.: 0.75 mm²
Conductor cross section solid max.: 16 mm²
Conductor cross section flexible min.: 0.75 mm²
Conductor cross section flexible max.: 10 mm²
Conductor cross section AWG min.: 20
Conductor cross section AWG max.: 4
Stripping length: 18 mm
Connection method: Push-in connection
Conductor cross section solid min.: 0.2 mm²
Conductor cross section solid max.: 1.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 1.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 16
Stripping length: 8 mm
EMC requirements for noise immunity: EN 61000-6-1
EMC requirements for noise emission: EN 61000-6-3
Standard - Safety of power supply units up to 1100 V (insulation distances): DIN EN 61558-2-16
Standard - Electrical safety: IEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations: EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage: IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolation: DIN VDE 0100-410
Standard – Limitation of mains harmonic currents: EN 61000-3-2
Rail applications: EN 50121-4
UL approvals: UL Listed UL 508
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Low Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
Conducted noise emission: EN 55016
Noise emission: EN 55016
Electrostatic discharge: EN 61000-4-2
Contact discharge: 6 kV (Test Level 3)
Discharge in air: 8 kV (Test Level 3)
Electromagnetic HF field: EN 61000-4-3
Frequency range: 80 MHz ... 6 GHz
Test field strength: 10 V/m (Test Level 3)
Frequency range: 80 MHz ... 6 GHz
Test field strength: 10 V/m (Test Level 3)
Frequency range: 80 MHz ... 6 GHz
Test field strength: 10 V/m (Test Level 3)
Comments: Criterion A
Fast transients (burst): EN 61000-4-4
Input: 4 kV (Test Level 3 - asymmetrical)
Output: 2 kV (Test Level 3 - asymmetrical)
Signal: 2 kV (Test Level 3 - asymmetrical)
Comments: Criterion A
Surge voltage load (surge): EN 61000-4-5
Input: 3 kV (Test Level 4 - symmetrical)
Output: 1 kV (Test Level 3 - symmetrical)
Signal: 1 kV (Test Level 2 - asymmetrical)
Comments: Criterion A
Conducted interference: EN 61000-4-6
Frequency range: 0.15 MHz ... 80 MHz
Voltage: 10 V (Test Level 3)
Comments: Criterion A
Voltage dips: EN 61000-4-11
Voltage: 230 V AC
Frequency: 50 Hz
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C: Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
REACh SVHC: Lead 7439-92-1
China RoHS: Environmentally Friendly Use Period = 25;
eCl@ss 10.0.1: 27040701
eCl@ss 4.0: 27040700
eCl@ss 4.1: 27040700
eCl@ss 5.0: 27049000
eCl@ss 5.1: 27049000
eCl@ss 6.0: 27049000
eCl@ss 7.0: 27049002
eCl@ss 8.0: 27049002
eCl@ss 9.0: 27040701
ETIM 4.0: EC002540
ETIM 5.0: EC002540
ETIM 6.0: EC002540
ETIM 7.0: EC002540
UNSPSC 13.2: 39121004
UNSPSC 18.0: 39121004
UNSPSC 19.0: 39121004
UNSPSC 20.0: 39121004
UNSPSC 21.0: 39121004

Logistic parameters

ECCN:
Country of Origin: CN
EAN:
Weight: 2.85 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m