308627
ICE1-16DIO-G60L-C1-V1D
Fieldbus module
Ethernet IO module with 16 configurable digital inputs/outputs and integrated logicfa. The ICE1-16DIO-G60L-C1-V1D is a multiprotocol fieldbus module with 16 digital in- or outputs. The G60L design in fully cast metal housing is resistant to mechanical damage and environmental influences. The G60L has protection class IP65/IP67. The fieldbus module serves as an interface between the controller of a fieldbus system and the field level. Thanks to its multiprotocol capability, the fieldbus module supports the Ethernet communication protocols PROFINET, EtherNet/IP, and EtherCAT. An L-coded M12 connector plug used for supplying power enables a current rating of up to 2 x 16 A. The inputs are equipped with. A-coded M12 connector plugs. Connection to the fieldbus is achieved using a D-coded M12 connector plug. The communication protocols are configured either manually via a rotary switch or automatically. The diagnostics display status information for each channel via LEDs. An integrated web server enables access to the fieldbus module. Information regarding the status of the module is also displayed and network parameters such as the IP address and subnet mask can be configured. The distributed logic function of the fieldbus module allows decentralized applications to be controlled autonomously.
UL File Number: | E223772 |
LED indication: | see manual |
Rotary switch: | Setting the fieldbus protocol |
Rated operating voltage: | 18 ... 30 V |
Nominal voltage: | 24 V DC |
Current consumption: | 120 mA |
Current loading capacity: | Max. 2 x 16 A per module (Loop-through current via L-coded power supply) Total current: max. 9 A per module |
Interface type: | Industrial Ethernet |
Physical: | M12, D-coded |
Protocol: | PROFINET IO with media redundancy protocol (MRP) EtherNet/IP with Device Level Ring (DLR) EtherCAT |
Transfer rate: | 10/100 Mbps |
Number/Type: | 16 digital inputs/outputs, configurable Inputs: 2-, 3-, 4-wire PNP, DC, supply from US Outputs: 2-wire PNP, DC, supply from UL No galvanic isolation between US and UL short-circuit protected |
Sensor supply: | max. 500 mA Per port (X1 - X8) via US |
Output rated operating current: | max. 2 A per channel (X1 - X8) / 4 A Per port via UL |
Electromagnetic compatibility: Directive 2014/30/EU: | EN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011 |
Degree of protection: | EN 60529:2000 |
Emitted interference: | EN 61000-6-4:2007+A1:2011 |
Noise immunity: | EN 61000-6-2:2005 |
Shock resistance: | EN 61131-2:2004 |
Ambient temperature: | -20 ... 70 °C (-4 ... 158 °F) |
Storage temperature: | -40 ... 70 °C (-40 ... 158 °F) |
Cold start temperature: | -40 °C (-40 °F) |
Relative humidity: | max. 95 % |
Altitude: | 0 ... 2000 m |
Shock and impact resistance: | 50 g, 11 ms, all axes |
Vibration resistance: | 15 g at 5 - 500 Hz |
Pollution degree: | 3 |
Contact elements: | PA |
Degree of protection: | IP65/IP67/IP69K |
Connection: | Power Supply M12, L-coded Fieldbus M12, D-coded Inputs M12, A-coded |
Material: Contacts: | CuSn, gold-plated CuNi, gold-plated |
Material: Housing: | Diecast zinc |
Material: Seal: | FKM |
Mass: | 500 g |
Tightening torque, fastening screws: | 1 Nm |
Tightening torque, cable gland: | max. 0.5 Nm |
Construction type: | Field housing |
Tightening torque of clamping screws: | 0.5 Nm |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.00 kg |
Length: | 0.00 m |
Width: | 0.00 m |