295313
ICE1-8IOL-G60L-V1D
IO-Link Master
Ethernet IO-Link module with 8 inputs/outputsfa. The module is a multiprotocol fieldbus module with 4 type A and 4 type B IOLink master ports according to IO-Link standard V1.1. The design in fully cast metal housing is resistant to mechanical damage and due to its high degree of protection to environmental influences. The fieldbus module serves as an interface between the controller of a fieldbus system and the field level. Thanks to its multiprotocol capability, the fieldbus module supports the Ethernet communication protocols PROFINET and EtherNet/IP. An L-coded M12 connector plug used for supplying power enables a current rating of up to 2 x 16 A. The inputs and outputs are equipped with A-coded M12 connector plugs. Connection to the fieldbus is achieved using a D-coded M12 connector plug. The communication protocols are configured either manually via a rotary switch or automatically. Status information for each channel is displayed via LEDs as a diagnostic function. An integrated web server enables access to the fieldbus module. Information regarding the status of the module is also displayed and network parameters such as the IP address and subnet mask can be configured.
UL File Number: | E223772 |
LED indication: | see manual |
Rotary switch: | Setting the fieldbus protocol |
Rated operating voltage: | 18 ... 30 V |
Nominal voltage: | 24 V DC |
Current consumption: | typ. 200 mA |
Current loading capacity: | Max. 2 x 16 A per module (Loop-through current via L-coded power supply) Total current: max. 9 A per module |
Galvanic isolation: | between US and UL |
Interface type: | Industrial Ethernet |
Physical: | M12, D-coded |
Protocol: | PROFINET IO with media redundancy protocol (MRP) EtherNet/IP with Device Level Ring (DLR) |
Transfer rate: | 10/100 Mbps |
Number/Type: | 4 x IO-Link Class A (X1 – X4) 4 x IO-Link Class B (X5 – X8) Configurable as: max. 8 IO-Link and 4 digital inputs and outputs max. 12 digital inputs and 4 digital outputs max. 12 digital outputs and 4 digital inputs short-circuit protected |
Sensor supply: | max. 500 mA Per port (X1 - X8) Via L+ (pin 1) |
Output rated operating current: | max. 500 mA Per port (X1 - X8) Via C/Q (pin 4) In addition, a maximum of 2 A per port (X5 – X8) Via UAux (pin 2) |
Electromagnetic compatibility: Directive 2014/30/EU: | EN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011 |
Degree of protection: | EN 60529:2000 |
Fieldbus standard: | Type 1 according to IEC 61131-2 |
Emitted interference: | EN 61000-6-4:2007+A1:2011 |
Noise immunity: | EN 61000-6-2:2005 |
Shock resistance: | EN 61131-2:2004 |
Ambient temperature: | -20 ... 70 °C (-4 ... 158 °F) |
Storage temperature: | -40 ... 70 °C (-40 ... 158 °F) |
Cold start temperature: | -40 °C (-40 °F) |
Relative humidity: | max. 95 % |
Altitude: | 0 ... 2000 m |
Shock and impact resistance: | 50 g, 11 ms, all axes |
Vibration resistance: | 15 g at 5 - 500 Hz |
Pollution degree: | 3 |
Contact elements: | PA |
Degree of protection: | IP65/IP67/IP69K |
Connection: | Power Supply M12, L-coded Fieldbus M12, D-coded Inputs/Outputs M12, A-coded |
Material: Contacts: | CuSn, gold-plated CuNi, gold-plated |
Material: Housing: | Diecast zinc |
Material: Seal: | FKM |
Mass: | 500 g |
Tightening torque, fastening screws: | 1 Nm |
Tightening torque, cable gland: | max. 0.5 Nm |
Construction type: | Field housing |
Tightening torque of clamping screws: | 0.5 Nm |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.00 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |