Pepperl+Fuchs 283692

KFD2-STC4-Ex1.H

SMART Transmitter Power Supply

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

This isolated barrier is used for intrinsic safety applications. 1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA, Terminals with test points, High field voltage 17.6 V DC, Up to SIL 2 acc. to IEC 61508pa. The device supplies 2-wire and 3-wire SMART transmitters with higher output voltage in a hazardous area, and can also be used with 2-wire SMART current sources. It transfers the analog input signal to the safe area as an isolated current value. Digital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally. If the HART communication resistance in the loop is too low, the internal resistance of 250 Ω between terminals 8 and 9 can be used. Test sockets for the connection of HART communicators are integrated into the terminals of the device.

Technical parameters

Signal type: Analog input
Safety Integrity Level (SIL): SIL 2
Connection: Power Rail or terminals 14+, 15-
Rated voltage: 20 ... 35 V DC
Ripple: within the supply tolerance
Power dissipation: 1.5 W
Power consumption: 1.9 W
Connection side: field side
Connection: terminals 1+, 2-, 3 or 5-, 6+
Input signal: 0/4 ... 20 mA
Voltage drop: ≤ 2.4 V at 20 mA (terminals 5, 6)
Input resistance: ≤ 64 Ω terminals 2-, 3 ; ≤ 500 Ω terminals 1+, 3 (250 Ω load)
Available voltage: ≥ 17.6 V at 20 mA terminals 1+, 3
Connection side: control side
Connection: terminals 7-, 8+, 9
Load: 0 ... 800 Ω at 20 mA
Output signal: 0/4 ... 20 mA (overload > 25 mA)
Ripple: max. 50 µA rms
Deviation: at 20 °C (68 °F), 0/4 ... 20 mA ≤ 10 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage
: Influence of ambient temperature: 0.25 µA/K
Frequency range: field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 7.5 kHz (-3 dB) control side into the field side: bandwidth with 0.5 Vpp signal 0.3 ... 7.5 kHz (-3 dB)
Settling time: 200 µs
Rise time/fall time: 20 µs
Output/power supply: functional insulation, rated insulation voltage 50 V AC
Display elements: LED
Labeling: space for labeling at the front
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013 (industrial locations)
Electromagnetic compatibility: NE 21:2011
Degree of protection: IEC 60529:2001
Protection against electrical shock: UL 61010-1:2012
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Degree of protection: IP20
Connection: screw terminals
Mass: approx. 200 g
Dimensions: 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2
Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001
EU-type examination certificate: BAS 99 ATEX 7060 X
Electromagnetic compatibility: Marking: II (1)G [Ex ia Ga] IIC , II (1)D [Ex ia Da] IIIC , I (M1) [Ex ia Ma] I
Electromagnetic compatibility: Input: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supply: Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.)
Equipment: terminals 1+, 3-
Supply: Voltage Uo: 27.2 V
Supply: Current Io: 93 mA
Supply: Power Po: 632 mW
Supply: Internal capacitance Ci: 12 nF
Supply: Internal inductance Li: 0 mH
Equipment: terminals 2-, 3
Supply: Voltage Ui: 30 V
Supply: Current Ii: 117 mA
Supply: Voltage Uo: 3.5 V
Supply: Current Io: 73 mA
Supply: Power Po: 64 mW
Equipment: terminals 1+, 2 / 3-
Supply: Voltage Uo: 27.2 V
Supply: Current Io: 117 mA
Supply: Power Po: 639 mW
Supply: Internal capacitance Ci: 12 nF
Supply: Internal inductance Li: 0 mH
Equipment: terminals 5-, 6+
Supply: Voltage Ui: 30 V
Supply: Current Ii: 117 mA
Supply: Voltage Uo: 8.7 V
Supply: Current Io: 0 mA
Supply: Internal capacitance Ci: 0 nF
Supply: Internal inductance Li: 0 mH
Output: Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.)
Certificate: TÜV 99 ATEX 1499 X
Output: Marking: II 3G Ex nA II T4 [device in zone 2]
Galvanic isolation: Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Galvanic isolation: Input/power supply: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
UL approval: Control drawing: 116-0428 (cULus)
IECEx approval: IECEx BAS 04.0016X IECEx CML 15.0055X
UL approval: Approved for: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Ex nA IIC T4 Gc
Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Logistic parameters

ECCN:
Country of Origin: SG
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m