248860
NBB4-12GK50-E3-M
Inductive sensor
Series: Cylindrical type, Housing material: PBT, Output type: 3-wire, Installation: flush, Type of voltage: DC, Connection type: cable PUR , 2 m, Degree of protection: IP68 / IP69Kfa
| Switching function: | Normally closed (NC) |
| Output type: | PNP |
| Rated operating distance: | 4 mm |
| Installation: | flush |
| Output polarity: | DC |
| Assured operating distance: | 0 ... 3.24 mm |
| Actuating element: | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm |
| Reduction factor rAl: | 0.35 |
| Reduction factor rCu: | 0.25 |
| Reduction factor r304: | 0.7 |
| Reduction factor rBrass: | 0.4 |
| Output type: | 3-wire |
| Operating voltage: | 5 ... 60 V |
| Switching frequency: | 0 ... 2500 Hz |
| Hysteresis: | typ. 5 % |
| Reverse polarity protection: | reverse polarity protected |
| Short-circuit protection: | pulsing |
| Inductive overvoltage protection: | yes |
| Surge suppression: | yes |
| Voltage drop: | ≤ 2 V |
| Rated insulation voltage: | 60 V |
| Operating current: | 0 ... 200 mA |
| Off-state current: | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current: | ≤ 7 mA |
| Switching state indicator: | LED, yellow |
| MTTFd: | 1006 a |
| Mission Time (TM): | 20 a |
| Diagnostic Coverage (DC): | 0 % |
| UL approval: | cULus Listed, General Purpose |
| CSA approval: | cCSAus Listed, General Purpose |
| CCC approval: | Certified by China Compulsory Certification (CCC) |
| E1 Type approval: | 10R-04 |
| Ambient temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Connection type: | cable PUR , 2 m |
| Core cross-section: | 3 x 0.75 mm2 |
| Housing material: | PBT |
| Sensing face: | PBT |
| Housing diameter: | 12 mm |
| Degree of protection: | IP68 / IP69K |
| Mass: | 110 g |
| ECCN: | |
| Country of Origin: | Vietnam |
| EAN: | 4050143040360 |
| Weight: | 0.12 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |