188869
MB-FB-4R.HO.SC
High-Density Fieldbus Power Hub, Motherboard for Honeywell C-Series
The FieldConnex. Universal Power Hub is a modular fieldbus power supply, providing the most options for most reliable communication. It supports explosion protection e.g. the High-Power Trunk for longest cable run and highest device count. The Power Hub supports optional Advanced Diagnostics for fast fieldbus commissioning and online monitoring. 4 segments, redundant, individual modules per segment, Customized for Honeywell, C-Series, High-power trunk: Live work on devices in any hazardous area, Optimized for size and quality, low heat dissipation, For FOUNDATION Fieldbus H1pa. The motherboard is the mounting plate for installation in the Honeywell C-channel. It connects to existing bulk power, communication and fault indication. Sockets for all modules enable simple installation and replacement without tools. For power redundancy with seamless transfer, pairs of modules feed each segment. Availability and a long service life are achieved through: only one passive impedance filter per segment with CREST for superior signal transmission, optimized design for low power dissipation and high-availability fieldbus termination. Any mounting direction allows optimized and space-saving cabinet layout.
Design / Mounting: | Motherboard based |
Connection: | Channel or external supply |
Rated voltage: | 19.2 ... 35 V SELV/PELV |
Rated current: | 6.3 A |
Power dissipation: | typ. 0.2 W per segment |
Number of segments: Redundant: | 4 |
Host-side: | Honeywell Series C 300 System Connector |
Terminating resistor: | integrated 100 Ω |
Fault signal: | to Honeywell C 300 System |
Fieldbus segment/Fieldbus segment: | functional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff |
Fieldbus segment/Supply: | functional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff |
Electromagnetic compatibility: Directive 2004/108/EC: | EN 61326-1:2006 |
Electromagnetic compatibility: | NE 21:2006 |
Degree of protection: | IEC 60529 |
Fieldbus standard: | IEC 61158-2 |
Shock resistance: | EN 60068-2-27 |
Vibration resistance: | EN 60068-2-6 |
Ambient temperature: | -40 ... 60 °C (-40 ... 140 °F) |
Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
Relative humidity: | < 95 % non-condensing |
Shock resistance: | 15 g , 11 ms |
Vibration resistance: | 1 g , 10 ... 150 Hz |
Connection type: | Honeywell channel or plug with screw flange |
Core cross-section: | 2.5 mm2 if supplied via plug with screw flange |
Housing width: | 150 mm |
Housing height: | 146 mm |
Housing depth: | 75 mm |
Degree of protection: | IP00 |
Mass: | approx. 720 g |
Mounting: | Honeywell channel |
FM approval: FM certificate: | FM 19 US 0015 X and FM 19 CA 0011 X |
FM approval: FM marking: | AEx/Ex ec IIC T4 |
Supplementary information: | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
ECCN: | |
Country of Origin: | Singapur |
EAN: | 4050143060634 |
Weight: | 0.85 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |