53800327
RSL455P-XL/CU400P-3M12
RSL455P-XL/CU400P-3M12 - Safety laser scanner
| Series: | RSL 400 |
| Application: | Mobile danger zone guarding, Mobile side guarding, Stationary access guarding, Stationary danger zone guarding |
| Special version: | Measurement data output optimized for vehicle navigation |
| Functions: | Four-field mode, Data output, configurable, PROFIsafe, Resolution, selectable |
| Type: | 3, IEC/EN 61496 |
| SIL: | 2, IEC 61508 |
| SILCL: | 2, IEC/EN 62061 |
| Performance Level (PL): | d, EN ISO 13849-1 |
| PFHD: | 9E-08 per hour |
| Mission time: | 20 years, EN ISO 13849-1 |
| Category: | 3, EN ISO 13849 |
| Scanning angle: | 270 ° |
| Minimum adjustable range: | 50 mm |
| Number of field pairs, reversible: | Up to 100 |
| Number of quads, reversible: | 50 |
| Number of protective functions: | 2 Piece(s) |
| Number of independent sensor configurations: | Up to 10 |
| Diffuse reflection, min.: | 1.8 % |
| Operating range: | 0 ... 8.25 m |
| Number of field pairs: | Up to 100 |
| Operating range: | 0 ... 20 m |
| Object size: | 150 mm x 150 mm |
| Diffuse reflection, min.: | 10 % |
| Light source: | Laser, Infrared |
| Laser light wavelength: | 905 nm |
| Laser class: | 1, IEC/EN 60825-1:2007 |
| Transmitted-signal shape: | Pulsed |
| Repetition frequency: | 90 kHz |
| Detection range: | 0 ... 50 m, Diffuse reflection > 90% |
| Diffuse reflection: | 20 % |
| Angular resolution: | 0.1 ° |
| Distance resolution, radial: | 1 mm |
| Distance resolution, lateral: | 0.1 ° |
| Systematic measurement error Dmeas - Dreal: | min.: -20 mm typ.: -10 mm max.: 0 mm (Diffuse reflection: 1.8% … retro-reflector Measurement range: 0.2 … 25 m) |
| Measurement value noise: | 10 mm, 1 σ (• Diffuse reflection: 1.8% … 20% Measurement range: 0 … 9 m • Diffuse reflection: 20% … retro-reflector Measurement range: 0 … 25 m) |
| Laser spot (H x W), 10 m: | 60 mm x 13 mm |
| Laser spot (H x W), 20 m: | 165 mm x 24 mm |
| Laser spot (H x W), 30 m: | 265 mm x 40 mm |
| Laser spot (H x W), 40 m: | 285 mm x 57 mm |
| Protective circuit: | Overvoltage protection |
| Supply voltage UB: | 24 V, DC, -30 ... 20 % |
| Current consumption (without load), max.: | 900 mA, (use power supply unit with 3 A) |
| Power consumption, max.: | 22 W, For 24 V, plus output load |
| Type: | PROFINET |
| Function: | Process |
| PROFINET device: | Device acc. to Spec V2.3.4 |
| GSDML: | GSDML acc. to Spec V2.3.2 |
| Profile: | PROFINET/PROFIsafe |
| Conformance class: | C |
| Network load class: | III |
| Security level: | 1 |
| Switch functionality: | IRT-ready 2-port switch acc. to IEEE 802, integrated in connection unit |
| Port properties: | Auto-Negotiation, Auto-Crossover, Auto-Polarity |
| I&M: | 0 - 4 |
| Supported topologies: | MRP client, SNMP |
| Safety-related switching signals: | 4 Piece(s) |
| Type: | Bluetooth, USB |
| Function: | Configuration/parametering |
| Frequency band: | 2,400 ... 2,483.5 MHz |
| Radiated transmitting power: | Max. 4.5 dBm (2.82 mW), class 2 |
| Function: | Configuration/parametering |
| Connection: | USB 2.0 mini-B, socket |
| Transmission speed, max.: | 12 Mbit/s |
| Cable length: | ≤ 5m Longer cable lengths are possible using active cables. |
| Number of connections: | 3 Piece(s) |
| Function: | Voltage supply |
| Type of connection: | Connector |
| Thread size: | M12 |
| Type: | Male |
| Material: | Metal |
| No. of pins: | 4 -pin |
| Encoding: | A-coded |
| Function: | PROFINET/PROFIsafe communication, input |
| Type of connection: | Connector |
| Thread size: | M12 |
| Type: | Female |
| Material: | Metal |
| No. of pins: | 4 -pin |
| Encoding: | D-coded |
| Function: | PROFINET/PROFIsafe communication, output |
| Type of connection: | Connector |
| Thread size: | M12 |
| Type: | Female |
| Material: | Metal |
| No. of pins: | 4 -pin |
| Encoding: | D-coded |
| Dimension (W x H x L): | 140.2 mm x 170 mm x 142 mm |
| Housing material: | Metal, Diecast zinc, Plastic |
| Lens cover material: | Plastic/PC |
| Net weight: | 4,300 g |
| Housing color: | Yellow, RAL 1021 |
| Type of fastening: | Mounting plate, Through-hole mounting, Via optional mounting device |
| Type of display: | LED indicator, Alphanumerical display |
| Number of LEDs: | 11 Piece(s) |
| Type of configuration: | Software Sensor Studio |
| Operational controls: | Software Sensor Studio |
| Ambient temperature, operation: | 0 ... 50 °C |
| Ambient temperature, storage: | -20 ... 60 °C |
| Relative humidity (non-condensing): | 15 ... 95 % |
| Degree of protection: | IP 65 |
| Protection class: | III, EN 61140 |
| Certifications: | TÜV Süd |
| Test procedure for EMC in accordance with standard: | DIN 40839-1/3, EN 61496-1 |
| Test procedure for oscillation in accordance with standard: | EN 60068-2-6 |
| Test procedure for continuous shock in accordance with standard: | IEC 60068-2-29 |
| US patents: | US 8,520,221 B, US 10,304,307B, US 7,656,917 B, US 7,696,468 B |
| Customs tariff number: | 85365019 |
| eCl@ss 8.0: | 27272705 |
| eCl@ss 9.0: | 27272705 |
| ETIM 5.0: | EC002550 |
| ETIM 6.0: | EC002550 |
| ECCN: | |
| Country of Origin: | Deutschland |
| EAN: | |
| Weight: | 0.00 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |