For the reliable vibration monitoring of machines and equipment. Condition-based maintenance thanks to monitoring of unbalance, rolling element bearing or gear state. Inputs for the simultaneous detection of up to four vibration sensors. Two switching outputs for pre-alarm and main alarm. Analogue inputs for monitoring further measurement variables

Technical parameters

Frequency range [Hz]: 0...12000
Design: parameter setting via PC software VES004
Operating voltage tolerance [%]: 20
Operating voltage [V]: 24 DC
Current consumption [mA]: 200; ((24 V DC))
Protection class: III
Total number of inputs and outputs: 8; (configurable)
Number of inputs and outputs: Number of analogue inputs: 2; Number of digital outputs: 2; Number of analogue outputs: 1
Total number of inputs: 6
Number of analogue inputs: 2; (static)
Analogue input (current) [mA]: 0...20
Resolution of analogue input: 12
Dynamic input - signal: 0...10 mA IEPE / 0...20 mA
Dynamic input - resolution [bit]: 16
Dynamic input - frequency range [Hz]: 0...12000
Dynamic input - sampling rate [kSamples]: 100
Total number of outputs: 2
Output signal: switching signal; analogue signal
Electrical design: PNP
Number of digital outputs: 2; (configurable)
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 100
Number of analogue outputs: 1; (configurable)
Analogue current output [mA]: 0...22
Max. load [Ω]: 500
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Frequency range [Hz]: 0...12000
Communication interface: Ethernet
Protocol: PROFINET IO
Ambient temperature [°C]: 0...60
Storage temperature [°C]: 0...60
Protection: IP 20
EMC: EN 61000-4-2 ESD 4 kV contact discharge / 15 kV air discharge EN 61000-4-3 10 V/m (80...2700 MHz) EN 61000-4-4 Burst 4 kV capacitive coupling probe, earthed EN 61000-4-6 10 V 0,15...80 MHz EN 61000-6-4 industrial environments EN 50178
EN 61000-4-2 ESD: 4 kV contact discharge / 15 kV air discharge
EN 61000-4-3: 10 V/m (80...2700 MHz)
EN 61000-4-4 Burst: 4 kV capacitive coupling probe, earthed
EN 61000-4-6: 10 V 0,15...80 MHz
EN 61000-6-4: industrial environments
MTTF [years]: 91
UL approval: UL Approval no. L001
UL Approval no.: L001
Weight [K40]: 307
Housing: plastic housing
Type of mounting: rail; (TH35/EN60715)
Dimensions [mm]: 114.2 x 50 x 105.3
Materials: PA
Real-time clock: yes;
Accessories (optional): cross-over Ethernet patch cable for the direct connection to the PC
Pack quantity: 1 pcs.
Connection: COMBICON:

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.31 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m