TW7011
Infrared temperature sensor. TW-008CODM30-QFPKG/US
Reliable, non-contact detection of objects with very high temperatures. For applications in the steel and glass industries. Intuitive setting of the switching temperature via pushbutton and display. Switch points of the two switching outputs can be adjusted independently. With fibre optics and measuring head for use where space is restricted
Number of inputs and outputs: | Number of digital outputs: 2 |
Measuring range: | 350...1350 °C 662...2462 °F |
350...1350 °C: | 662...2462 °F |
Application: | tempering temperatures; graphite; ceramics; metals; forging; sintering; heat treatment; rolling |
Operating voltage [V]: | 10...34 DC |
Current consumption [mA]: | 30; (24 V) |
Protection class: | III |
Number of inputs and outputs: | Number of digital outputs: 2 |
Test input: | test function active at U(test) > 9 V |
Total number of outputs: | 2 |
Output signal: | switching signal |
Electrical design: | PNP |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2.5 |
Permanent current rating of switching output DC [mA]: | 150 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Wave length range [µm]: | 1...1.7 |
Measuring range: | 350...1350 °C 662...2462 °F |
350...1350 °C: | 662...2462 °F |
Factory setting: | SP1 = 25 %; rP1 = 23 %; SP2 = 75 %; rP2 = 73 % |
Set point SP: | 350...1340 °C 662...2444 °F |
350...1340 °C: | 662...2444 °F |
Reset point rP: | 350...1340 °C 662...2444 °F |
350...1340 °C: | 662...2444 °F |
In steps of: | 10 °C 18 °F |
10 °C: | 18 °F |
Resolution of switching output [K]: | 10 |
Resolution of display [K]: | 10 |
Accuracy [K]: | < ± 1 %; (of VMR (degree of emission = 1 and T = 23 °C)) |
Response time [ms]: | 2 |
Adjustment of the switch point: | programming buttons |
Parameter setting options: | Hysteresis; normally open / normally closed; switch-on/switch-off delay |
Ambient temperature [°C]: | 0...65 |
Storage temperature [°C]: | -20...80 |
Max. relative air humidity [%]: | 95; (non condensing) |
Protection: | IP 65 |
EMC: | DIN EN 61000-4-2 ESD 4 kV CD / 8 kV AD DIN EN 61000-4-3 HF radiated 10 V/m DIN EN 61000-4-4 Burst 2 kV coupling clamp DIN EN 61000-4-5 Surge 0,5 / 1 kV DIN EN 61000-4-6 HF conducted 10 V EN 55011 emission class B |
DIN EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
DIN EN 61000-4-3 HF radiated: | 10 V/m |
DIN EN 61000-4-4 Burst: | 2 kV coupling clamp |
DIN EN 61000-4-5 Surge: | 0,5 / 1 kV |
DIN EN 61000-4-6 HF conducted: | 10 V |
EN 55011 emission: | class B |
Shock resistance: | DIN EN 60068-2-27 30 g (11 ms) |
DIN EN 60068-2-27: | 30 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 5 g (10...2000 Hz) |
DIN EN 60068-2-6: | 5 g (10...2000 Hz) |
MTTF [years]: | 117 |
Weight [g]: | 374 |
Housing: | threaded type |
Dimensions [mm]: | M30 x 1.5 / L = 163 |
Thread designation: | M30 x 1.5 |
Fibre optic connection: | ¼"-36UNS-2A |
Materials: | threaded sleeve: stainless steel (1.4305 / 303); polyester |
Lens material: | tempered optical glass |
Display: | switching status 2 x LED, yellow function display 7-segment LED display, 2-digit measured values 7-segment LED display, 2-digit |
switching status: | 2 x LED, yellow |
function display: | 7-segment LED display, 2-digit |
measured values: | 7-segment LED display, 2-digit |
Operating elements: | 3 pushbuttons |
3: | pushbuttons |
Accessories (supplied): | lock nuts: 2 |
Accessories (optional): | fibre optics:, E35061 / E35062 Measuring head:, E35060 |
Remarks: | MW = measured value MEW = Final value of the measuring range |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.37 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |