TV7303
Temperature sensor with IO-Link. TV7-030FLEN12-QFRVG/US
High precision across the entire temperature measurement range. Particularly good response dynamics and very short power-on delay time. Robust stainless steel housing with very high pressure rating. Two programmable switching outputs. Continuous transmission of process values via IO-Link
Number of inputs and outputs: | Number of digital outputs: 2 |
Measuring range [°F]: | -58...302 |
Process connection: | threaded connection 1/2" NPT |
Installation length EL [mm]: | 30 |
Special feature: | Gold-plated contacts |
Measuring element: | 1 x Pt 1000; (to DIN EN 60751, class A) |
Media: | liquids and gases |
Pressure rating [bar]: | 300 |
Note on pressure rating: | sensor When mounted in adapters the specifications of the adapter data sheet apply. |
Operating voltage [V]: | 18...32 DC; ("supply class 2" to cULus) |
Current consumption [mA]: | < 50 |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 1 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 2 |
Total number of outputs: | 2 |
Output signal: | switching signal; IO-Link; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2.5 |
Permanent current rating of switching output DC [mA]: | 100 |
Measuring range [°F]: | -58...302 |
Set point SP [°F]: | -57.6...302 |
Reset point rP [°F]: | -58...301.6 |
In steps of [°F]: | 0.1 |
Resolution of switching output [K]: | 0.1 |
Switch point accuracy [K]: | ± 0,3 |
Temperature drift per 10 K [K]: | 0.1 **) |
Dynamic response T05 / T09 [s]: | 1 / 3; (to DIN EN 60751) |
Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
Ambient temperature [°C]: | -40...80 |
Note on ambient temperature: | at medium temperature: < 125 °C -40...50 °C at medium temperature: < 150 °C |
Storage temperature [°C]: | -40...100 |
Protection: | IP 69K |
EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 542.6 |
UL approval: | UL Approval no. K019 |
UL Approval no.: | K019 |
Weight [g]: | 110 |
Materials: | stainless steel (1.4404 / 316L); FKM |
Materials (wetted parts): | stainless steel (1.4404 / 316L) |
Process connection: | threaded connection 1/2" NPT |
Probe diameter [mm]: | 6 |
Installation length EL [mm]: | 30 |
Remarks: | The values for accuracy apply to flowing water. |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | US |
EAN: | |
Weight: | 0.11 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |