Ifm TAD091

Temperature transmitter with drift detection. TAD050KLER12-A-ZKG/US

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Number of inputs and outputs: Number of digital outputs: 1; Number of analogue outputs: 1
Measuring range: -25...160 °C -13...320 °F
-25...160 °C: -13...320 °F
Process connection: threaded connection G 1/2 external thread
Installation length EL [mm]: 50
Special feature: Gold-plated contacts
Measuring element: 1 x Pt 1000 + 1 x NTC; (thermically coupled, with backup function (temperature measuring even if one element fails))
Media: liquids and gases
Pressure rating [bar]: 50
Minimum installation depth [mm]: 25
MAWP (for applications according to CRN) [bar]: 50
Operating voltage [V]: 18...32 DC; ("supply class 2" to cULus)
Current consumption [mA]: 6; (24 V)
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 8
Integrated watchdog: yes
Number of inputs and outputs: Number of digital outputs: 1; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; IO-Link; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 1
Output function: normally open / normally closed / diagnostic signal; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 150; (200 (...60°C); 250 (...40 °C))
Diagnostic output: diagnostic output for drift and fault monitoring
Number of analogue outputs: 1
Analogue current output [mA]: 4...20
Max. load [Ω]: (Ub - 15 V) x 50
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: -25...160 °C -13...320 °F
-25...160 °C: -13...320 °F
Note on measuring range: scalable
Factory setting: 0...150 °C / 32...302 °F
Drift warning: 0.2...5 °C 0.4...9 °F
0.2...5 °C: 0.4...9 °F
Drift alarm: 0.2...5 °C 0.4...9 °F
0.2...5 °C: 0.4...9 °F
In steps of: 0.05 °C 0.1 °F
0.05 °C: 0.1 °F
Resolution of analogue output [K]: 0.05
Precision analogue output [K]: ± 0,2 (-10...130°C); ± 0,3 (130...140°C); ± 0,3 ± 0,1% MS (-25...-10/140...160°C); (probe completely inserted into the measured medium up to the sealing chamfer)
Temperature coefficient [% of the span / 10 K]: < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C)
Dynamic response T05 / T09 [s]: 3 / 6
Parameter setting options: drift warning/drift alarm threshold; Fail-Safe; Display unit; scaling of the analogue output; redundancy switching; performance diagnostic output; switching logic; normally open / normally closed
Communication interface: IO-Link
Transmission type: COM1 (4,8 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9 CDV
IO-Link device ID: 323 d / 00 01 43 h
Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 1
Min. process cycle time [ms]: 18.8
Ambient temperature [°C]: -25...70
Storage temperature [°C]: -40...85
Protection: IP 68; IP 69K
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3
Shock resistance: DIN EN 68000-2-27 50 g (11 ms)
DIN EN 68000-2-27: 50 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 20 g (10...2000 Hz)
DIN EN 60068-2-6: 20 g (10...2000 Hz)
MTTF [years]: 213
Note on approval: Including free 5-point calibration certificate.
Weight [K40]: 335.5
Materials: stainless steel (1.4435 / 316L); stainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts): stainless steel (1.4435 / 316L); stainless steel (1.4404 / 316L)
Tightening torque [Nm]: 30...50
Process connection: threaded connection G 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts: Ra: < 0.6
Installation length EL [mm]: 50
Remarks: MS = set measuring span
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: US
EAN:
Weight: 0.34 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m