Ifm TA3231

TA-123.LDD06-A-ZVG/US/

Temperature transmitter. TA-123.LDD06-A-ZVG/US/

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

High precision across the entire temperature measurement range. Particularly good response dynamics and very short power-on delay time. Robust stainless steel housing with high pressure rating. Precise analogue output. High protection rating for the requirements of harsh industrial environments

Technical parameters

Number of inputs and outputs: Number of analogue outputs: 1
Measuring range: -10...150 °C 14...302 °F
-10...150 °C: 14...302 °F
Process connection: diameter Ø 6 mm
Installation length EL [mm]: 123
Special feature: Gold-plated contacts
Measuring element: 1 x Pt 1000; (to DIN EN 60751, class A)
Media: liquids and gases
Medium temperature: < 150; (< 40 min) °C < 302; (< 40 min) °F
< 150; (< 40 min) °C: < 302; (< 40 min) °F
Pressure rating [bar]: 50
Note on pressure rating: sensor When mounted in adapters the specifications of the adapter data sheet apply.
Minimum installation depth [mm]: 15
Operating voltage [V]: 10...30 DC
Protection class: III
Reverse polarity protection: yes
Number of inputs and outputs: Number of analogue outputs: 1
Total number of outputs: 1
Output signal: analogue signal
Number of analogue outputs: 1
Analogue current output [mA]: 4...20
Max. load [Ω]: 500
Overload protection: yes
Probe length L [mm]: 123
Measuring range: -10...150 °C 14...302 °F
-10...150 °C: 14...302 °F
Resolution of analogue output [K]: 0.02
Precision analogue output [K]: ± 0,3
Temperature coefficient [% of the span / 10 K]: < ± 0,1; (in case of deviation from the reference condition 25 ± 5 °C)
Dynamic response T05 / T09 [s]: 1,2 / 3,5; (to DIN EN 60751)
Ambient temperature [°C]: -25...70
Storage temperature [°C]: -40...100
Protection: IP 68; IP 69K
EMC: DIN EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m DIN EN 61000-4-4 Burst 2 kV DIN EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V
DIN EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
DIN EN 61000-4-4 Burst: 2 kV
DIN EN 61000-4-5 Surge: 0,5/1 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN EN 60068-2-27 50 g (11 ms)
DIN EN 60068-2-27: 50 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 10 g (10...2000 Hz)
DIN EN 60068-2-6: 10 g (10...2000 Hz)
MTTF [years]: 1119
Weight [g]: 165.8
Dimensions [mm]: Ø 30 / L = 171
Materials: stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); PA
Materials (wetted parts): stainless steel (1.4404 / 316L)
Process connection: diameter Ø 6 mm
Probe diameter [mm]: 6
Installation length EL [mm]: 123
Remarks: The values for accuracy apply to flowing water. referring to UL: for use on a low voltage circuit with overcurrent protection in accordance with UL873 tab. 28.1 or Imax = 100/Ub (Ub = voltage of the circuit)
Notes: discontinued article
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: USA
EAN:
Weight: 0.17 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m