TA2313
Temperature transmitter. TA-050FLEN12-A-ZVG/US
High precision across the entire temperature measurement range. Particularly good response dynamics and very short power-on delay time. Robust stainless steel housing with very high pressure rating. Precise analogue output and user-friendly communication via IO-Link. High protection rating for the requirements of harsh industrial environments
| Number of inputs and outputs: | Number of analogue outputs: 1 |
| Measuring range [°F]: | -58...302 |
| Process connection: | threaded connection 1/2" NPT |
| Installation length EL [mm]: | 50 |
| Special feature: | Gold-plated contacts |
| Measuring element: | 1 x Pt 1000; (to DIN EN 60751, class A) |
| Media: | liquids and gases |
| Pressure rating [bar]: | 300 |
| Note on pressure rating: | sensor When mounted in adapters the specifications of the adapter data sheet apply. |
| MAWP (for applications according to CRN) [bar]: | 300 |
| Operating voltage [V]: | 18...32 DC; ("supply class 2" to cULus) |
| Current consumption [mA]: | < 50 |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 1 |
| Number of inputs and outputs: | Number of analogue outputs: 1 |
| Total number of outputs: | 1 |
| Output signal: | analogue signal; IO-Link; (configurable) |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20 |
| Max. load [Ω]: | 250; ((18...19 V); 19...32 V: 300 Ω) |
| Short-circuit protection: | yes |
| Overload protection: | yes |
| Measuring range [°F]: | -58...302 |
| Factory setting: | 0...300 °F |
| Resolution of analogue output [K]: | 0.04 |
| Precision analogue output [K]: | ± 0,3 + (± 0,1 % MS) |
| Temperature coefficient [% of the span / 10 K]: | 0,1; (in case of deviation from the reference condition 25 ± 5 °C) |
| Dynamic response T05 / T09 [s]: | 1 / 3 |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.1 |
| Ambient temperature [°C]: | -25...80 |
| Storage temperature [°C]: | -40...100 |
| Protection: | IP 67; IP 68; IP 69K |
| EMC: | DIN EN 61000-6-2 |
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
| DIN IEC 68-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
| MTTF [years]: | 572 |
| UL approval: | UL Approval no. K002 |
| UL Approval no.: | K002 |
| Weight [g]: | 132.5 |
| Dimensions [mm]: | Ø 18.7 |
| Materials: | stainless steel (1.4404 / 316L); PEI; FKM |
| Materials (wetted parts): | stainless steel (1.4404 / 316L) |
| Process connection: | threaded connection 1/2" NPT |
| Probe diameter [mm]: | 6 |
| Installation length EL [mm]: | 50 |
| Display: | operating status 1 x LED, green |
| operating status: | 1 x LED, green |
| Remarks: | MS = set measuring span |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Country of Origin: | US |
| EAN: | |
| Weight: | 0.13 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |