SU8001
Ultrasonic flow meter. SUR11HGBFRKG/W/US-100-IPF
Precise measurement of flow, consumption and medium temperature. Suitable for water, oils and glycol solutions. For installation in pipes. With switching output, analogue output and pulse output. Clearly visible 4-digit LED display
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Process connection: | threaded connection G 1 flat seal |
| Measuring range [°F]: | 14...176 |
| Special feature: | Gold-plated contacts |
| Application: | totaliser function; for industrial applications |
| Installation: | connection to pipe by means of an adapter |
| Media: | water; glycol solutions; coolants; oil |
| Note on media: | low-viscosity oils with viscosity: 7...40 mm²/s (40 °C) high-viscosity oils with viscosity: 30...68 mm²/s (40 °C) |
| Medium temperature [°F]: | 14...176 |
| Pressure rating [bar]: | 16 |
| Pressure rating [psi]: | 232 |
| Operating voltage [V]: | 19...30 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA]: | 100 |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 10 |
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Inputs: | counter reset |
| Total number of outputs: | 2 |
| Output signal: | switching signal; analogue signal; pulse signal; (configurable) |
| Electrical design: | PNP/NPN |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2 |
| Permanent current rating of switching output DC [mA]: | 250; (per output) |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20; (scalable) |
| Max. load [Ω]: | 500 |
| Analogue voltage output [V]: | 0...10; (scalable) |
| Min. load resistance [Ω]: | 2000 |
| Pulse output: | flow rate meter |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Measuring range: | 0...1585 gph 0...26.44 gpm |
| 0...1585 gph: | 0...26.44 gpm |
| Display range: | 0...1902 gph 0...31.72 gpm |
| 0...1902 gph: | 0...31.72 gpm |
| Resolution: | 1 gph 0.02 gpm |
| 1 gph: | 0.02 gpm |
| Set point SP: | 4...1585 gph 0.06...26.44 gpm |
| 4...1585 gph: | 0.06...26.44 gpm |
| Reset point rP: | 0...1581 gph 0...26.38 gpm |
| 0...1581 gph: | 0...26.38 gpm |
| Analogue start point ASP: | 0...1285 gph 0...21.44 gpm |
| 0...1285 gph: | 0...21.44 gpm |
| Analogue end point AEP: | 300...1585 gph 5...26.44 gpm |
| 300...1585 gph: | 5...26.44 gpm |
| Max. flow rate: | 1902 gph 31.7 gpm |
| 1902 gph: | 31.7 gpm |
| In steps of: | 1 gph 0.02 gpm |
| 1 gph: | 0.02 gpm |
| Pulse value: | 0.02...9000 * 10³ gal |
| In steps of: | 0.02 gal |
| Pulse length [s]: | 0,3...2 |
| Measuring range [°F]: | 14...176 |
| Resolution [°F]: | 0.5 |
| Set point SP [°F]: | 14.5...176 |
| Reset point rP [°F]: | 14...175.5 |
| Analogue start point [°F]: | 14...145.5 |
| Analogue end point [°F]: | 44.5...176 |
| In steps of [°F]: | 0.5 |
| Accuracy (in the measuring range): | < ± (3 % MW + 0,2 % MEW) / < ± (5 % MW + 0,5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) |
| Repeatability: | 0,05 gpm; 3 gph |
| Accuracy [K]: | ± 5,4 (Q > 0,26 gpm) |
| Response time [s]: | 0.25; (dAP = 0) |
| Delay time programmable dS, dr [s]: | 0...50 |
| Damping for the switching output dAP [s]: | 0...1 |
| Dynamic response T05 / T09 [s]: | T09 = 70 (Q > 1 gpm); (water) |
| Parameter setting options: | Flow monitoring; quantity meter; Preset counter; Temperature monitoring |
| Ambient temperature [°F]: | 14...140 |
| Storage temperature [°F]: | -13...176 |
| Protection: | IP 67 |
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5 kV EN 61000-4-6 HF conducted 10 V |
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 10 V/m |
| EN 61000-4-4 Burst: | 2 kV |
| EN 61000-4-5 Surge: | 0,5 kV |
| EN 61000-4-6 HF conducted: | 10 V |
| Shock resistance: | DIN IEC 68-2-27 20 g (11 ms) |
| DIN IEC 68-2-27: | 20 g (11 ms) |
| Vibration resistance: | DIN IEC 68-2-6 5 g (10...2000 Hz) |
| DIN IEC 68-2-6: | 5 g (10...2000 Hz) |
| MTTF [years]: | 185 |
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g]: | 1666.5 |
| Materials: | housing: AlMgSi0,5 anodised; Sealing: FKM; connector housing: brass Optalloy-plated; PA 6.6; cover film: PA |
| Materials (wetted parts): | stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 |
| Process connection: | threaded connection G 1 flat seal |
| Display: | Display unit 5 x LED, green (gpm, gph, gal, °F, 10³) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit |
| Display unit: | 5 x LED, green (gpm, gph, gal, °F, 10³) |
| switching status: | 2 x LED, yellow |
| measured values: | alphanumeric display, 4-digit |
| programming: | alphanumeric display, 4-digit |
| Accessories (supplied): | sealings: 2, Centellen |
| Accessories (optional): | adapter for pipe: 1 x 1/2" NPT, stainless steel, E40192 adapter for pipe: 1 x 3/4" NPT, stainless steel, E40193 adapter for pipe: 1 x 1/2" NPT, brass, E40155 adapter for pipe: 1 x 3/4" NPT, brass, E40156 |
| Remarks: | MW = measured value MEW = Final value of the measuring range sealing: only with supplied Centellen seals |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 1.67 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |