Ifm SR5906

Control monitor for flow sensors. SRM12XXAKOW/LS-100-IRF

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Reliable monitoring of liquids and gases in pipes. For the connection of flow sensors with large immersion depths. For sensors made of ceramics, high-grade stainless steel and titanium. Easy setting of the switch points for quick set-up. LED bar graph for indication of switch point and flow

Technical parameters

Application: Flow monitoring; Wire monitoring
Frequency AC [Hz]: 47...63
Operating voltage tolerance [%]: -15...10
Operating voltage [V]: 90...240 AC
Max. power consumption [VA]: 3.5
Protection class: II
Reverse polarity protection: no
Power-on delay time [s]: 10
Number of channels: 1
Electrical design: relay
Contact rating: 3 A (250 V AC / 30 V DC); (switching cycles at 3 A load: 100.000; type of switch-off: normally open)
Switching cycles (mechanical): 20_Millionen
Switching function flow monitoring: output switches when flow is present: ON for output function = normally open / OFF for output function = normally closed
Short-circuit protection: no
Overload protection: no
Adjustment of the switch point: pushbutton
Ambient temperature [°C]: -20...60
Protection: IP 67; (with sensor attached)
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 30 g (6 ms)
DIN IEC 68-2-27: 30 g (6 ms)
Vibration resistance: DIN IEC 68-2-6 5 g (55...2000 Hz)
DIN IEC 68-2-6: 5 g (55...2000 Hz)
MTTF [years]: 209
Weight [g]: 244.5
Materials: stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass
Display: function LED, bar graph switching status LED, orange flash in case of wire break
function: LED, bar graph
switching status: LED, orange flash in case of wire break
Required protection: miniature fuse to IEC60127-2 sheet 1; ≤ 5 A; fast acting
Remarks: Connection for flow sensor without short-circuit protection / reverse polarity protection. The flow sensor must be directly connected to the control monitor. A connection by means of extension cables is not allowed. Recommendation Check the safe functioning of the unit after a short circuit.
Pack quantity: 1 pcs.
Connection: Connector: 1 x 1/2"

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.24 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m