Ifm SM9100

Magnetic-inductive flow meter. SMR21XGXFRKG/US

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Precise measurement of flow, consumption and medium temperature. High accuracy, repeatability and measurement dynamics. Precise empty pipe detection. With switching output, analogue output and pulse output. Clearly visible 4-digit LED display

Technical parameters

Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Process connection: threaded connection G 2 DN50 flat seal
Measuring range [°C]: -20...80
Special feature: Gold-plated contacts
Application: totaliser function; empty pipe detection; for industrial applications
Installation: connection to pipe by means of an adapter
Media: conductive liquids; water; hydrous media
Note on media: conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]: -10...70
Pressure rating [bar]: 16
Pressure rating [Mpa]: 1.6
MAWP (for applications according to CRN) [bar]: 16.5
Operating voltage [V]: 18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 150
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 5
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Inputs: counter reset
Total number of outputs: 2
Output signal: switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250; (per output)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Analogue voltage output [V]: 0...10; (scalable)
Min. load resistance [Ω]: 2000
Pulse output: flow rate meter
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Frequency of the output [Hz]: 0.1...10000
Measuring range: 5...300 l/min 0.3...18 m³/h
5...300 l/min: 0.3...18 m³/h
Display range: -360...360 l/min -21.6...21.6 m³/h
-360...360 l/min: -21.6...21.6 m³/h
Resolution: 0.5 l/min 0.02 m³/h
0.5 l/min: 0.02 m³/h
Set point SP: 6.5...300 l/min 0.4...18 m³/h
6.5...300 l/min: 0.4...18 m³/h
Reset point rP: 5...298.5 l/min 0.3...17.9 m³/h
5...298.5 l/min: 0.3...17.9 m³/h
Analogue start point ASP: 0...240 l/min 0...14.4 m³/h
0...240 l/min: 0...14.4 m³/h
Analogue end point AEP: 60...300 l/min 3.6...18 m³/h
60...300 l/min: 3.6...18 m³/h
Low flow cut-off LFC: < 15 l/min < 0.9 m³/h
< 15 l/min: < 0.9 m³/h
In steps of: 0.5 l/min 0.02 m³/h
0.5 l/min: 0.02 m³/h
Measuring dynamics: 1:60
Pulse value: 0.0001...300 x 10³ m³
In steps of: 0.0001 m³
Pulse length [s]: 0,016...2
Measuring range [°C]: -20...80
Display range [°C]: -40...100
Resolution [°C]: 0.2
Set point SP [°C]: -19.2...80
Reset point rP [°C]: -19.6...79.6
Analogue start point [°C]: -20...60
Analogue end point [°C]: 0...80
In steps of [°C]: 0.2
Accuracy (in the measuring range): ± (0,8 % MW + 0,5 % MEW)
Repeatability: ± 0,2% MEW
Temperature drift: ± 0,0333 °C / K
Accuracy [K]: ± 1 (25 °C; Q > 15 l/min)
Response time [s]: 0.35; (dAP = 0)
Delay time programmable dS, dr [s]: 0...50
Damping for the switching output dAP [s]: 0...5
Dynamic response T05 / T09 [s]: T09 = 3 (Q > 15 l/min)
Parameter setting options: Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9 CDV
IO-Link device ID: 359 d / 00 01 67 h
Profiles: Smart Sensor: Process Data Variable; Device Identification
SIO mode: yes
Required master port type: A
Process data analogue: 3
Process data binary: 2
Min. process cycle time [ms]: 5
Ambient temperature [°C]: -10...60
Storage temperature [°C]: -25...80
Protection: IP 65; IP 67
EMC: DIN EN 60947-5-9
Shock resistance: DIN EN 60068-2-27 20 g (11 ms)
DIN EN 60068-2-27: 20 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 5 g (10...2000 Hz)
DIN EN 60068-2-6: 5 g (10...2000 Hz)
MTTF [years]: 78
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 3214
Materials: stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts): stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; EPDM
Process connection: threaded connection G 2 DN50 flat seal
Display: Display unit 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit
Display unit: 6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status: 2 x LED, yellow
measured values: alphanumeric display, 4-digit
programming: alphanumeric display, 4-digit
Accessories (supplied): sealings: 2, Centellen Label
Remarks: MW = measured value MEW = Final value of the measuring range
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 3.21 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m