SM9004
Magnetic-inductive flow meter. SMR21XGX50KG/US
Precise measurement of flow, consumption and medium temperature. High accuracy, repeatability and measurement dynamics. For use in water cooling circuits. With two precise analogue outputs. Clearly visible 4-digit LED display
Number of inputs and outputs: | Number of analogue outputs: 2 |
Process connection: | threaded connection G 2 DN50 flat seal |
Measuring range: | -20...80 °C -4...176 °F |
-20...80 °C: | -4...176 °F |
Special feature: | Gold-plated contacts |
Application: | empty pipe detection; for industrial applications |
Installation: | connection to pipe by means of an adapter |
Media: | conductive liquids; water; hydrous media |
Note on media: | conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C) |
Medium temperature: | -10...70 °C 14...158 °F |
-10...70 °C: | 14...158 °F |
Pressure rating [bar]: | 16 |
Pressure rating [Mpa]: | 1.6 |
Pressure rating [psi]: | 232 |
MAWP (for applications according to CRN) [bar]: | 16.5 |
Operating voltage [V]: | 18...32 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | < 150 |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 5 |
Number of inputs and outputs: | Number of analogue outputs: 2 |
Total number of outputs: | 2 |
Output signal: | analogue signal |
Number of analogue outputs: | 2 |
Analogue current output [mA]: | 4...20; (≤ 22 mA; scalable) |
Max. load [Ω]: | 500 |
Measuring range: | 5...300 l/min 0.3...18 m³/h 80...4755 gph 1.3...79.3 gpm |
5...300 l/min: | 0.3...18 m³/h |
Display range: | -360...360 l/min -21.6...21.6 m³/h -5705...5705 gph -95.1...95.1 gpm |
-360...360 l/min: | -21.6...21.6 m³/h |
Resolution: | 0.5 l/min 0.02 m³/h 5 gph 0.1 gpm |
0.5 l/min: | 0.02 m³/h |
Analogue start point ASP: | 0...240 l/min 0...14.4 m³/h 0...3800 gph 0...63.4 gpm |
0...240 l/min: | 0...14.4 m³/h |
Analogue end point AEP: | 60...300 l/min 3.6...18 m³/h 955...4755 gph 15.9...79.3 gpm |
60...300 l/min: | 3.6...18 m³/h |
Low flow cut-off LFC: | < 15 l/min < 0.9 m³/h < 240 gph < 4 gpm |
< 15 l/min: | < 0.9 m³/h |
In steps of: | 0.5 l/min 0.02 m³/h 5 gph 0.1 gpm |
0.5 l/min: | 0.02 m³/h |
Measuring dynamics: | 1:60 |
Measuring range: | -20...80 °C -4...176 °F |
-20...80 °C: | -4...176 °F |
Display range: | -40...100 °C -40...212 °F |
-40...100 °C: | -40...212 °F |
Resolution: | 0.2 °C 0.5 °F |
0.2 °C: | 0.5 °F |
Analogue start point: | -20...60 °C -4...140 °F |
-20...60 °C: | -4...140 °F |
Analogue end point: | 0...80 °C 32...176 °F |
0...80 °C: | 32...176 °F |
In steps of: | 0.2 °C 0.5 °F |
0.2 °C: | 0.5 °F |
Accuracy (in the measuring range): | ± (0,8 % MW + 0,5 % MEW) |
Repeatability: | ± 0,2% MEW |
Temperature drift: | ± 0,0333 °C / K; ± 0,0599 °F / K |
Accuracy [K]: | ± 1 (25 °C; Q > 15 l/min) / ± 1 (77 °F; Q > 4 gpm) |
Response time [s]: | 0.35; (dAP = 0) |
Damping for the switching output dAP [s]: | 0...5 |
Dynamic response T05 / T09 [s]: | T09 = 3 (Q > 15 l/min) / T09 = 3 (Q > 4 gpm) |
Parameter setting options: | display can be deactivated; Display unit; empty pipe detection |
Ambient temperature: | -10...60 °C 14...140 °F |
-10...60 °C: | 14...140 °F |
Storage temperature: | -25...80 °C -13...176 °F |
-25...80 °C: | -13...176 °F |
Protection: | IP 65; IP 67 |
EMC: | DIN EN 60947-5-9 |
Shock resistance: | DIN EN 60068-2-27 20 g (11 ms) |
DIN EN 60068-2-27: | 20 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 5 g (10...2000 Hz) |
DIN EN 60068-2-6: | 5 g (10...2000 Hz) |
MTTF [years]: | 78 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 3140.5 |
Materials: | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U |
Materials (wetted parts): | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM |
Process connection: | threaded connection G 2 DN50 flat seal |
Display: | Display unit 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F) function display 1 x LED, yellow (10³) measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit |
Display unit: | 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F) |
function display: | 1 x LED, yellow (10³) |
measured values: | alphanumeric display, 4-digit |
programming: | alphanumeric display, 4-digit |
Display unit: | l/min; m³/h; gpm; gph; °C; °F |
Accessories (supplied): | sealings: 2, Centellen Label |
Remarks: | MW = measured value MEW = Final value of the measuring range |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 3.14 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |