Ifm SM9001

Magnetic-inductive flow meter. SMR21XGXFRKG/US

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Precise measurement of flow, consumption and medium temperature. High accuracy, repeatability and measurement dynamics. Precise empty pipe detection. With switching output, analogue output and pulse output. Clearly visible 4-digit LED display

Technical parameters

Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Process connection: threaded connection G 2 DN50 flat seal
Measuring range [°F]: -4...176
Special feature: Gold-plated contacts
Application: totaliser function; empty pipe detection; for industrial applications
Installation: connection to pipe by means of an adapter
Media: conductive liquids; water; hydrous media
Note on media: conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C)
Medium temperature [°F]: 14...158
Pressure rating [bar]: 16
MAWP (for applications according to CRN) [bar]: 16.5
Operating voltage [V]: 18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 150
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 5
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Inputs: counter reset
Total number of outputs: 2
Output signal: switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250; (per output)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Analogue voltage output [V]: 0...10; (scalable)
Min. load resistance [Ω]: 2000
Pulse output: flow rate meter
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Frequency of the output [Hz]: 0.1...10000
Measuring range: 80...4800 gph 1.3...80 gpm
80...4800 gph: 1.3...80 gpm
Display range: -5760...5760 gph -96...96 gpm
-5760...5760 gph: -96...96 gpm
Resolution: 5 gph 0.1 gpm
5 gph: 0.1 gpm
Set point SP: 105...4800 gph 1.7...80 gpm
105...4800 gph: 1.7...80 gpm
Reset point rP: 80...4775 gph 1.3...79.6 gpm
80...4775 gph: 1.3...79.6 gpm
Analogue start point ASP: 0...3840 gph 0...64 gpm
0...3840 gph: 0...64 gpm
Analogue end point AEP: 960...4800 gph 16...80 gpm
960...4800 gph: 16...80 gpm
Low flow cut-off LFC: < 240 gph < 4 gpm
< 240 gph: < 4 gpm
In steps of: 5 gph 0.1 gpm
5 gph: 0.1 gpm
Measuring dynamics: 1:60
Pulse value: 0.02...80 E06 gal
In steps of: 0.02 gal
Pulse length [s]: 0,016...2
Measuring range [°F]: -4...176
Display range [°F]: -40...212
Resolution [°F]: 0.5
Set point SP [°F]: -2...176
Reset point rP [°F]: -3...175
Analogue start point [°F]: -4...140
Analogue end point [°F]: 32...176
In steps of [°F]: 0.5
Accuracy (in the measuring range): ± (0,8 % MW + 0,5 % MEW)
Repeatability: ± 0,2% MEW
Temperature drift: ± 0,0185 °F / K
Accuracy [K]: ± 1 (77 °F; Q > 4 gpm)
Response time [s]: 0.35; (dAP = 0)
Delay time programmable dS, dr [s]: 0...50
Damping for the switching output dAP [s]: 0...5
Dynamic response T05 / T09 [s]: T09 = 3 (Q > 4 gpm)
Parameter setting options: Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9 CDV
IO-Link device ID: 392d / 00 01 88h
Profiles: Smart Sensor: Process Data Variable; Device Identification
SIO mode: yes
Required master port type: A
Process data analogue: 3
Process data binary: 2
Min. process cycle time [ms]: 5
Ambient temperature [°F]: 14...140
Storage temperature [°F]: -13...176
Protection: IP 65; IP 67
EMC: DIN EN 60947-5-9
Shock resistance: DIN EN 60068-2-27 20 g (11 ms)
DIN EN 60068-2-27: 20 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 5 g (10...2000 Hz)
DIN EN 60068-2-6: 5 g (10...2000 Hz)
MTTF [years]: 78
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 3163
Materials: stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts): stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM
Process connection: threaded connection G 2 DN50 flat seal
Display: Display unit 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit
Display unit: 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
switching status: 2 x LED, yellow
measured values: alphanumeric display, 4-digit
programming: alphanumeric display, 4-digit
Accessories (supplied): sealings: 2, Centellen Label
Remarks: MW = measured value MEW = Final value of the measuring range
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 3.16 kg
Length: 0.00 m