Ifm SM8404

Magnetic-inductive flow meter. SMK11GGX50KG/US-100

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Number of inputs and outputs: Number of analogue outputs: 2
Process connection: threaded connection Rc 1 internal thread DN25
Measuring range [°C]: -20...80
Special feature: Gold-plated contacts
Application: for industrial applications
Media: conductive liquids; water; hydrous media
Note on media: conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]: -10...70
Pressure rating [bar]: 16
Pressure rating [Mpa]: 1.6
Operating voltage [V]: 20...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: 120; (24 V)
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 5
Number of inputs and outputs: Number of analogue outputs: 2
Total number of outputs: 2
Output signal: analogue signal
Number of analogue outputs: 2
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Overload protection: yes
Measuring range: 0.2...100 l/min 0.1...26.4 gpm
0.2...100 l/min: 0.1...26.4 gpm
Display range: -120...120 l/min -31.7...31.7 gpm
-120...120 l/min: -31.7...31.7 gpm
Resolution: 0.1 l/min 0.05 gpm
0.1 l/min: 0.05 gpm
Analogue start point ASP: 0...80 l/min 0...21.1 gpm
0...80 l/min: 0...21.1 gpm
Analogue end point AEP: 20...100 l/min 5.3...26.4 gpm
20...100 l/min: 5.3...26.4 gpm
In steps of: 0.1 l/min 0.05 gpm
0.1 l/min: 0.05 gpm
Measuring range [°C]: -20...80
Resolution [°C]: 0.2
Analogue start point [°C]: -20...60
Analogue end point [°C]: 0...80
In steps of [°C]: 0.2
Accuracy (in the measuring range): ± (0,2 % MW + 0,5 % MEW)
Repeatability: ± 0,2% MEW
Accuracy [K]: ± 2,5 (Q > 1 l/min)
Response time [s]: 0.15; (dAP = 0, T19)
Damping for the switching output dAP [s]: 0...3
Dynamic response T05 / T09 [s]: T09 = 20 (Q > 1 l/min)
Ambient temperature [°C]: -10...60
Storage temperature [°C]: -25...80
Protection: IP 67
EMC: DIN EN 60947-5-9 500 V withstand voltage (V DC)
DIN EN 60947-5-9: 500 V withstand voltage (V DC)
Shock resistance: DIN IEC 68-2-27 20 g (11 ms)
DIN IEC 68-2-27: 20 g (11 ms)
Vibration resistance: DIN IEC 68-2-6 5 g (10...2000 Hz)
DIN IEC 68-2-6: 5 g (10...2000 Hz)
MTTF [years]: 175
UL approval: UL Approval no. I011
UL Approval no.: I011
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [K40]: 646
Materials: stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts): stainless steel (1.4404 / 316L); PEEK; FKM
Process connection: threaded connection Rc 1 internal thread DN25
Display: Display unit 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F) measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit
Display unit: 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F)
measured values: alphanumeric display, 4-digit
programming: alphanumeric display, 4-digit
Remarks: MW = measured value MEW = Final value of the measuring range
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.65 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m