SM6601
Magnetic-inductive flow meter. SMN12GGXFRKG/US-100
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection: | threaded connection 1/2" NPT DN15 |
Measuring range [°F]: | -4...176 |
Special feature: | Gold-plated contacts |
Application: | totaliser function; for industrial applications |
Media: | conductive liquids; water; hydrous media |
Note on media: | conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C) |
Medium temperature [°F]: | 14...158 |
Pressure rating [bar]: | 16 |
Pressure rating [psi]: | 232 |
MAWP (for applications according to CRN) [bar]: | 17.7 |
Operating voltage [V]: | 18...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | 95; (24 V) |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 5 |
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs: | counter reset |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 200 |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20; (scalable) |
Max. load [Ω]: | 500 |
Analogue voltage output [V]: | 0...10; (scalable) |
Min. load resistance [Ω]: | 2000 |
Pulse output: | flow rate meter |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | 1.5...396 gph 0.03...6.6 gpm |
1.5...396 gph: | 0.03...6.6 gpm |
Display range: | -475.5...475.5 gph -7.925...7.925 gpm |
-475.5...475.5 gph: | -7.925...7.925 gpm |
Resolution: | 0.5 gph 0.01 gpm |
0.5 gph: | 0.01 gpm |
Set point SP: | 3.5...396.5 gph 0.06...6.6 gpm |
3.5...396.5 gph: | 0.06...6.6 gpm |
Reset point rP: | 1.5...394 gph 0.03...6.57 gpm |
1.5...394 gph: | 0.03...6.57 gpm |
Analogue start point ASP: | 0...318 gph 0...5.3 gpm |
0...318 gph: | 0...5.3 gpm |
Analogue end point AEP: | 78...396 gph 1.3...6.6 gpm |
78...396 gph: | 1.3...6.6 gpm |
In steps of: | 0.5 gph 0.01 gpm |
0.5 gph: | 0.01 gpm |
Pulse value: | 0.01...30 000 000 gal |
Pulse length [s]: | 0,01...2 |
Measuring range [°F]: | -4...176 |
Resolution [°F]: | 0.1 |
Set point SP [°F]: | -2.5...176 |
Reset point rP [°F]: | -3.5...175 |
Analogue start point [°F]: | -4...140.5 |
Analogue end point [°F]: | 31.5...176 |
In steps of [°F]: | 0.5 |
Accuracy (in the measuring range): | ± (0,8 % MW + 0,5 % MEW) |
Repeatability: | ± 0,2% MEW |
Accuracy [K]: | ± 4,5 (Q > 0,26 gpm) |
Response time [s]: | 0.15; (dAP = 0, T19) |
Delay time programmable dS, dr [s]: | 0...50 |
Damping for the switching output dAP [s]: | 0...5 |
Dynamic response T05 / T09 [s]: | T09 = 20 (Q > 0,26 gpm) |
Parameter setting options: | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 |
IO-Link device ID: | 570 / 00 02 3a h |
Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 3 |
Process data binary: | 2 |
Min. process cycle time [ms]: | 5 |
Ambient temperature [°F]: | 14...140 |
Storage temperature [°F]: | -13...176 |
Protection: | IP 67 |
EMC: | DIN EN 60947-5-9 |
Shock resistance: | DIN EN 68000-2-27 20 g (11 ms) |
DIN EN 68000-2-27: | 20 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 5 g (10...2000 Hz) |
DIN EN 60068-2-6: | 5 g (10...2000 Hz) |
MTTF [years]: | 145 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 586.5 |
Materials: | stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
Materials (wetted parts): | stainless steel (1.4404 / 316L); PEEK; FKM |
Process connection: | threaded connection 1/2" NPT DN15 |
Display: | Display unit 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit |
Display unit: | 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) |
switching status: | 2 x LED, yellow |
measured values: | alphanumeric display, 4-digit |
programming: | alphanumeric display, 4-digit |
Remarks: | MW = measured value MEW = Final value of the measuring range |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.59 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |