SM6420
Magnetic-inductive flow meter. SMK12XGXFRKG/US-100
Precise measurement of flow, consumption and medium temperature. High accuracy, repeatability and measurement dynamics. With switching output, analogue output and pulse output. Clearly readable colour display with red/green colour change. No inlet and output pipe lengths required
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range [l/min]: | 0.05...35 |
| Display range [l/min]: | -42...42 |
| Process connection: | Rc 1/2 DN15 |
| Special feature: | Gold-plated contacts |
| Media: | conductive liquids; water; hydrous media |
| Note on media: | Leitfähigkeit: ≥ 20 µS/cm Viskosität: < 70 mm²/s (40 °C) |
| Medium temperature [°C]: | -20...90 |
| Pressure rating [bar]: | 16 |
| Pressure rating [Mpa]: | 1.6 |
| Operating voltage [V]: | 18...30 DC; (nach EN 50178, SELV, PELV) |
| Current consumption [mA]: | < 80 |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 5 |
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Inputs: | counter reset |
| Total number of outputs: | 2 |
| Output signal: | switching signal; analogue signal; pulse signal; IO-Link; frequency signal; (configurable) |
| Electrical design: | PNP/NPN |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2 |
| Permanent current rating of switching output DC [mA]: | 100 |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20; (scalable) |
| Max. load [Ω]: | 500 |
| Pulse output: | flow rate meter |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Measuring range [l/min]: | 0.05...35 |
| Display range [l/min]: | -42...42 |
| Resolution [l/min]: | 0.02 |
| Set point SP [l/min]: | 0.25...35 |
| Reset point rP [l/min]: | 0...34.8 |
| Analogue start point ASP [l/min]: | 0...28 |
| Analogue end point AEP [l/min]: | 7...35 |
| Low flow cut-off LFC [l/min]: | 0.05...1.75 |
| Frequency end point, FEP [l/min]: | 7...35 |
| Frequency at the end point FRP [Hz]: | 1...10000 |
| Pulse length [s]: | 0.001...2 |
| Pulse value: | 0.001...99990000 I |
| Measuring range [°C]: | -20...90 |
| Display range [°C]: | -42...112 |
| Resolution [°C]: | 0.1 |
| Set point SP [°C]: | -19.6...90 |
| Reset point rP [°C]: | -20...89.6 |
| Analogue start point [°C]: | -20...68 |
| Analogue end point [°C]: | 2...90 |
| In steps of [°C]: | 0.1 |
| Accuracy (in the measuring range): | ± (0,8 % MW + 0,2 % MEW) |
| Repeatability: | ± 0,2 % MEW |
| Accuracy [K]: | ± 2,5 (Q > 5 % MEW) |
| Start-up delay [s]: | 0...50 |
| Response time [s]: | < 0.25; (dAP = 0, T09) |
| Damping for the switching output dAP [s]: | 0...5 |
| Response time [s]: | 15; (Q > 10 % MEW, T09) |
| Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; frequency output; current/pulse output; start-up delay; display can be deactivated; Display unit |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.1 |
| SDCI standard: | IEC 61131-9 |
| IO-Link device ID: | 954 d / 00 03 ba h |
| Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode: | yes |
| Required master port type: | A |
| Process data analogue: | 3 |
| Process data binary: | 2 |
| Min. process cycle time [ms]: | 6 |
| Ambient temperature [°C]: | -20...60 |
| Storage temperature [°C]: | -25...80 |
| Protection: | IP 65; IP 67 |
| EMC: | DIN EN 60947-5-9 |
| Shock resistance: | DIN IEC 68-2-27 20 g (11 ms) |
| DIN IEC 68-2-27: | 20 g (11 ms) |
| Vibration resistance: | DIN IEC 68-2-6: 5 g (10...2000 Hz) |
| DIN IEC 68-2-6:: | 5 g (10...2000 Hz) |
| MTTF [years]: | 114 |
| UL approval: | UL Approval no. I014 File number UL E174189 |
| UL Approval no.: | I014 |
| File number UL: | E174189 |
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g]: | 733.6 |
| Materials: | stainless steel (1.4408/316); stainless steel (1.4404 / 316L); PC; PBT+PC-GF30 |
| Materials (wetted parts): | stainless steel (1.4404 / 316L); PEEK; carbon fibre PEEK; FKM |
| Process connection: | Rc 1/2 DN15 |
| Display: | colour display 1,44", 128 x 128 pixels 2 x LED, yellow |
| Remarks: | MW = measured value MEW = Final value of the measuring range |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: vergoldet |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.73 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |