SM6050
Magnetic-inductive flow meter. SMR12GGX1OKG/US-100
Number of inputs and outputs: | Number of analogue outputs: 1 |
Process connection: | threaded connection G 1/2 DN15 flat seal |
Special feature: | Gold-plated contacts |
Application: | for industrial applications |
Installation: | connection to pipe by means of an adapter |
Media: | conductive liquids; water; hydrous media |
Note on media: | conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C) |
Medium temperature [°C]: | -10...70 |
Pressure rating [bar]: | 16 |
Pressure rating [Mpa]: | 1.6 |
MAWP (for applications according to CRN) [bar]: | 17.7 |
Operating voltage [V]: | 18...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | 95; (24 V) |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 5 |
Number of inputs and outputs: | Number of analogue outputs: 1 |
Total number of outputs: | 1 |
Output signal: | analogue signal; IO-Link; (configurable) |
Permanent current rating of switching output DC [mA]: | 250 |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20 |
Max. load [Ω]: | 500 |
Overload protection: | yes |
Measuring range [l/min]: | 0.1...25 |
Accuracy (in the measuring range): | ± (0,8 % MW + 0,5 % MEW) |
Repeatability: | ± 0,2% MEW |
Response time [s]: | 0.15; (dAP = 0, T19) |
Dynamic response T05 / T09 [s]: | T09 = 20 (Q > 1 l/min) |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 |
IO-Link device ID: | 571 / 00 02 3b h |
Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 2 |
Min. process cycle time [ms]: | 3 |
Ambient temperature [°C]: | -10...60 |
Storage temperature [°C]: | -25...80 |
Protection: | IP 67 |
EMC: | DIN EN 60947-5-9 |
Shock resistance: | DIN IEC 68-2-27 20 g (11 ms) |
DIN IEC 68-2-27: | 20 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 5 g (10...2000 Hz) |
DIN IEC 68-2-6: | 5 g (10...2000 Hz) |
MTTF [years]: | 167 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [K40]: | 491 |
Materials: | stainless steel (1.4404 / 316L); PBT-GF20; FKM; TPE |
Materials (wetted parts): | stainless steel (1.4404 / 316L); PEEK; FKM |
Process connection: | threaded connection G 1/2 DN15 flat seal |
Remarks: | MW = measured value MEW = Final value of the measuring range |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.49 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |