SF5701
Flow sensor for connection to an evaluation unit. SFD10ADT /US-100
Reliable monitoring of liquids and gases in pipes. For connection to an evaluation unit. Simple process connection via adapter. Titanium materials for contact with the medium for use in aggressive media. M12 connector for fast and easy connection
Probe length L [mm]: | 63 |
Process connection: | M18 x 1,5 internal thread |
Media: | Liquids; Gases; aggressive media |
Medium temperature [°C]: | -25...80 |
Pressure rating [bar]: | 100 |
Connection to control monitor: | VS3000 |
Probe length L [mm]: | 63 |
Setting range [cm/s]: | 3...300 |
Greatest sensitivity [cm/s]: | 3...60 |
Setting range [cm/s]: | 200...3000 |
Greatest sensitivity [cm/s]: | 200...800 |
Temperature gradient [K/min]: | 300 |
Response time [s]: | 1...10 |
Storage temperature [°C]: | -25...80 |
Protection: | IP 67 |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 10 g (55...2000 Hz) |
DIN IEC 68-2-6: | 10 g (55...2000 Hz) |
MTTF [years]: | 8393.77 |
Weight [K40]: | 63.5 |
Housing: | for adapter |
Dimensions [mm]: | M18 x 1.5 |
Thread designation: | M18 x 1.5 |
Materials: | titanium (3.7035); EPDM; ULTEM |
Materials (wetted parts): | titanium (3.7035); O-ring: FKM 80 Shore A |
Process connection: | M18 x 1,5 internal thread |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Maximum cable length: 100 m |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.06 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |